Table 4-5: kontron fru info agent sensor, Ils see 4.3.1.1 oem sensor description, 1 oem sensor description – Kontron AT8404 User Manual

Page 75

Advertising
background image

Software Description

62

AT8404 User Guide

www.kontron.com

4.3.1.1

OEM sensor description

Kontron FRU Info Agent

Table 4-5:

Kontron FRU info agent sensor

Event/Reading

type code

Sensor type

Sensor specific

offset

Event trigger

0x0A

0xC5
OEM Kontron
FRU Info Agent

0x06

Transition to degraded

Event Data 2 is used a bit flag error

Bit 7: unspecifiedError
Bit 6: notPresentError
Bit 5: multirecHeaderError
Bit 4: multirecDataError
Bit 3: timeout error
Bit 2: ipmcError
Bit 1: fruDataError
Bit 0: commonHeaderError
Event Data 3 is used a bit flag error
Bit 7: reserved
Bit 6: reserved
Bit 5: SetPortState Not Supported
Bit 4: SetPortState Error
Bit 3: reserved
Bit 2: reserved
Bit 1: reserved
Bit 0: Match Error, Not in single link matches

0x08

Install Error
Event Data 2 is used a bit flag error
Bit 7: unspecifiedError
Bit 6: notPresentError
Bit 5: multirecHeaderError
Bit 4: multirecDataError
Bit 3: timeout error
Bit 2: ipmcError
Bit 1: fruDataError
Bit 0: commonHeaderError
Event Data 3 is used a bit flag error
Bit 7: SetClockState Not Supported
Bit 6: SetClockState Error
Bit 5: SetPortState Not Supported
Bit 4: SetPortState Error
Bit 3: Clock Internal Mismatch
Bit 2: Clock Match Error, Not a single clock matches
Bit 1: Internal mismatch
Bit 0: Match Error, Not in single link matches

Advertising