3.13

Fan Connector (FAN_CPU)

The

FAN_CPU is used for the connection of the FAN for the CPU.

The

FAN_SYS can be used to power, control and monitor a fan for chassis ventilation etc.

The 4pin header is recommended to be used for driving 4-wire type Fan in order to implement FAN speed

control. 3-wire Fan is also possible, but no fan speed control is integrated.

4-pin Mode:

PIN

Signal

Type Ioh/Iol Pull

U/D

Note

1

CONTROL

O

-

-

2

SENSE

I

-

4K7

3

+12V

PWR

-

-

4

GND

PWR

-

-

Signal

Description

CONTROL PWM signal for FAN speed control

SENSE

Tacho signal from the fan for supervision. The signals shall be generated by an open

collector transistor or similar. On-board is a pull-up resistor 4K7 to +12V. The signal has to

be pulsed, typically twice per rotation.

12V

+12V supply for fan. A maximum of 2000mA can be supplied from this pin.

GND

Power Supply GND signal

3-pin Mode:

PIN

Signal

Type Ioh/Iol Pull

U/D

Note

-

2

SENSE

I

-

4K7

3

+12V

PWR

-

-

4

GND

PWR

-

-

Signal

Description

SENSE

Tacho signal from the fan for supervision. The signals shall be generated by an open

collector transistor or similar. On-board is a pull-up resistor 4K7 to +12V. The signal has to

be pulsed, typically twice per rotation.

12V

+12V supply for fan. A maximum of 2000mA can be supplied from this pin.

GND

Power Supply GND signal