18 feature connector (feature), Feature connector (feature), Connector definitions – Kontron KTGM45-mITX User Manual

Page 54

Advertising
background image

KTGM45 Users Guide

KTD-N0793-O

Page 54

3.18

Feature Connector (FEATURE)

Note Pull

U/D

Ioh/

Iol Type

Signal

PIN

Signal Type Ioh/

Iol

Pull

U/D Note

2

2M/

-

I

INTRUDER#

1 2

GND

PWR

-

-

O

S5#

3 4

EXT_SMI#

I

4K7

3

O

PWR_OK

5 6

SB5V

PWR

-

-

-

-

PWR

SB3V3

7 8

EXT_BAT PWR

-

-

-

-

PWR

+5V

9 10

GND

PWR

-

-

1 4K7/ /12mA IOT

GPIO0

11 12

GPIO1

IOT /12mA 4K7/ 1

1 4K7/ /12mA IOT

GPIO2

13 14

GPIO3

IOT /12mA 4K7/ 1

1 4K7/ /12mA IOT

GPIO4

15 16

GPIO5

IOT /12mA 4K7/ 1

1 4K7/ /12mA IOT

GPIO6

17 18

GPIO7

IOT /12mA 4K7/ 1

-

-

PWR

GND

19 20

FAN3OUT O

4K7

3

FAN3IN

21 22

+12V

PWR

-

-

TEMP3IN

23 24

VREF

-

-

PWR

GND

25 26

IRRX

IRTX

27 28

GND

PWR

-

-

1 4K7/

SMBC

29 30

SMBD

4K7/ 1

Notes:

1. Pull-up to +3V3Dual (+3V3 or SB3V3).

2. Pull-up to on-board Battery.

3. Pull-up to +3V3.

Signal

Description

INTRUDER# INTRUDER, may be used to detect if the system case has been opened. This signal’s

status is readable, so it may be used like a GPI when the Intruder switch is not required.

S5#

S5 sleep mode, active low output, optionally used to deactivate external system when in

S5 sleep mode.

EXT_SMI#

External SMI, (active low input) signal can activate SMI interrupt.

PWR_OK

PoWeR OK, signal is high if no power failures are detected. (This is not the same as the

P_OK signal generated by ATX PSU).

SB5V

StandBy +5V supply.

SB3V3

Max. load is 0.75A (1.5A < 1 sec.)

EXT_BAT

(EXTernal BATtery) option for connecting + terminal of an external primary cell battery

(2.5 - 4.0 V) ( – terminal connected to GND etc. pin 10). The external battery is protected

against charging and can be used with or without the on-board battery installed.

+5V

Max. load is 0.75A (1.5A < 1 sec.)

GPIO0..7

General Purpose Inputs / Output. These Signals may be controlled or monitored through

the use of the KT-API-V2 (Application Programming Interface).

FAN3OUT

FAN 3 speed control OUTput. This 3.3V PWM signal can be used as Fan control voltage

(0–3.3V DC in 128 steps) via a Fan Driver Circuit (not included) to program Fan voltage.

For more info, see W83627 datasheet. Default PMW output is 127 (100% = 3.3V).

FAN3IN

FAN3 Input. 0V to +3V3 amplitude Fan 3 tachometer input.

+12V

Max. load is 0.75A (1.5A < 1 sec.)

TEMP3IN

Temperature sensor 3 input. (Recommended: Transistor 2N3904, having emitter

connected to GND (pin 25), collector and basis shorted and connected to pin 23. Further

a resistor 30K/1% shall be connected between pin 23 - 24. (Precision +/- 3ºC).

VREF

Voltage REFerence, reference voltage to be used with TEMP3IN input.

IRRX

IR Receive input (IrDA 1.0, SIR up to 1.152K bps)

IRTX

IR Transmit output (IrDA 1.0, SIR up to 1.152K bps)

SMBC

SMBus Clock signal

SMBD

SMBus Data signal

Connector Definitions

Advertising