Table 13 — Fan Performance, 48TF012 — Vertical Discharge Units (SI)

LEGEND

NOTES:

1. Boldface indicates field-supplied drive required. (See Note 5.)

2.

indicates field-supplied motor and drive are required.

3. Values include losses for filters, unit casing, and wet coils.
4. Use of a field-supplied motor may affect wire sizing. Contact

your Carrier representative to verify.

5. Standard drive range is 9.5 to 13.0 r/s. All other speeds require

a field-supplied drive.

6. Maximum continuous BkW is 1.79. Extensive motor and electri-

cal testing on these units ensures that the full range of the
motor can be utilized with confidence. Using the fan motors up
to the ratings shown will not result in nuisance tripping or pre-
mature motor failure. Unit warranty will not be affected.

7. Interpolation is permissible. Do not extrapolate.

AIRFLOW

(L/s)

EXTERNAL STATIC PRESSURE (Pa)

50

100

150

200

250

R/s

BkW

R/s

BkW

R/s

BkW

R/s

BkW

R/s

BkW

1500

9.8

0.55

10.9

0.67

12.0

0.79

12.9

0.92

13.8

1.04

1550

10.0

0.60

11.2

0.74

12.2

0.86

13.1

0.98

13.9

1.11

1600

10.3

0.66

11.4

0.80

12.4

0.92

13.3

1.05

14.2

1.18

1650

10.6

0.72

11.7

0.86

12.6

0.98

13.6

1.12

14.4

1.25

1700

10.9

0.78

12.0

0.93

12.8

1.06

13.7

1.20

14.6

1.34

1750

11.1

0.86

12.2

1.00

13.1

1.14

14.0

1.28

14.8

1.42

1800

11.4

0.93

12.5

1.08

13.3

1.22

14.2

1.36

15.0

1.52

1850

11.7

1.00

12.7

1.15

13.6

1.31

14.4

1.44

15.2

1.60

1900

12.0

1.08

12.9

1.23

13.8

1.40

14.6

1.53

15.4

1.70

1950

12.2

1.16

13.2

1.31

14.1

1.49

14.8

1.63

15.6

1.79

2000

12.5

1.25

13.4

1.40

14.3

1.59

15.1

1.74

15.9

1.90

2050

12.8

1.34

13.7

1.50

14.6

1.69

15.3

1.85

16.1

2.00

2100

13.1

1.44

13.9

1.60

14.9

1.80

15.6

1.97

16.3

2.12

2150

13.3

1.53

14.2

1.71

15.1

1.91

15.8

2.09

16.5

2.24

2200

13.6

1.64

14.5

1.82

15.3

2.02

16.1

2.21

16.8

2.37

2250

13.9

1.75

14.7

1.94

15.6

2.13

16.3

2.34

2300

14.2

1.86

15.0

2.06

15.8

2.25

16.6

2.47

2400

14.5

1.98

15.3

2.19

16.1

2.38

2450

14.8

2.10

15.6

2.32

AIRFLOW

(L/s)

EXTERNAL STATIC PRESSURE (Pa)

300

350

400

450

500

R/s

BkW

R/s

BkW

R/s

BkW

R/s

BkW

R/s

BkW

1500

14.6

1.15

15.3

1.26

16.1

1.38

16.9

1.45

17.7

1.68

1550

14.8

1.23

15.5

1.35

16.2

1.47

17.1

1.60

17.8

1.81

1600

15.0

1.30

15.7

1.44

16.4

1.55

17.1

1.68

17.9

1.86

1650

15.1

1.39

15.9

1.52

16.6

1.65

17.3

1.77

18.0

1.91

1700

15.3

1.47

16.1

1.61

16.8

1.74

17.4

1.88

18.1

2.00

1750

15.5

1.56

16.3

1.70

17.0

1.85

17.6

1.98

18.2

2.11

1800

15.8

1.66

16.4

1.80

17.2

1.95

17.8

2.09

18.4

2.22

1850

16.0

1.75

16.6

1.90

17.3

2.05

18.0

2.20

18.6

2.34

1900

16.2

1.86

16.9

2.01

17.5

2.16

18.2

2.31

1950

16.4

1.96

17.1

2.12

17.7

2.26

18.4

2.43

2000

16.6

2.07

17.3

2.24

17.9

2.39

2050

16.8

2.18

17.5

2.36

2100

17.0

2.30

2150

17.2

2.41

2200

2250

2300

2400

2450

BkW — Fan Input kW x Motor Efficiency
R/s

Revolutions Per Second of Blower Wheel

Advertising
This manual is related to the following products: