Fig. 6 — base unit dimensions – Carrier 48TFE008-014 User Manual

Page 7

Advertising
background image

7

BOTTOM POWER CHART, THESE HOLES
REQUIRED FOR USE WITH ACCESSORY

PACKAGES — CRBTMPWR002A00

(

POWER

AND CONTROL) AND CRBTMPWR004A00

(POWER, CONTROL, AND GAS)

THREADED

CONDUIT

SIZE

WIRE

USE

REQURED

HOLE SIZES

(MAX.)

1

/

2

″ ″

[12.7]

24 V

7

/

8

″″″″ [22.2]

1

1

/

4

″ ″

[31.7]

Power

1

3

/

4

″″″″ [44.4]

3/

4

″ ″

[19] FPT

Gas

1

5

/

8

″″″″ [41.3]

UNIT
48TF

STANDARD

UNIT WEIGHT

DURABLADE

ECONOMIZER

WEIGHT

ECONOMI$ER

WEIGHT

CORNER

WEIGHT (A)

CORNER

WEIGHT (B)

CORNER

WEIGHT (C)

CORNER

WEIGHT (D)

“H”

“J”

“K”

“L”

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

Lb

Kg

ft-in.

[mm]

ft-in.

[mm]

ft-in.

[mm]

ft-in.

[mm]

D/E/F008

870

395

44

20

62

28

189

86

161

73

239

109

280

127

1-2

7

/

8

[ 378] 3-5

5

/

16

[1050]

2-9

11

/

16

[856]

2- 2

7

/

16

[672]

D/E/F012

1035

469

44

20

62

28

225

102

192

87

285

129

333

151

2-5

7

/

8

[ 759] 4-1

5

/

16

[1253]

3-0

3

/

8

[924]

2-10

7

/

16

[875]

D/E014

1050

476

44

20

62

28

228

103

195

88

289

131

338

153

1-2

7

/

8

[ 378] 4-1

5

/

16

[1253]

3-0

3

/

8

[924]

2-10

7

/

16

[875]

CONNECTION SIZES

A

1

3

/

8

″″″″ Dia [35] Field Power Supply Hole

B

2

1

/

2

″″″″ Dia [64] Power Supply Knockout

C

1

3

/

4

″″″″ Dia [44] Charging Port Hole

D

7

/

8

″″″″ Dia [22] Field Control Wiring Hole

E

3

/

4

″ ″

″ [19] - 14 NPT Condensate Drain

F

1

/

2

″″″″ [13] - 14 NPT Gas Connection 48TFD008

3

/

4

″ ″

″ [19] - 14 NPT Gas Connection 48TFE,F008

48TFD,E012 & 014, 48TJF012

G

2

″″″″ Dia [51] Power Supply Knockout

NOTES:

1. Dimensions in [

] are in millimeters.

2.

Center of gravity.

3.

Direction of airflow.

4. On vertical discharge units, ductwork to be attached to

accessory roof curb only. For horizontal discharge units,
field-supplied flanges should be attached to horizontal dis-
charge openings, and all ductwork should be attached to
the flanges.

5. Minimum clearance (local codes or jurisdiction may prevail):

a. Between unit, flue side and combustible surfaces,

36 in. [914].

b. Bottom of unit to combustible surfaces (when not using

curb), 1 in. [25]. Bottom of base rail to combustible sur-
faces (when not using curb) 0 inches.

c. Condenser coil, for proper airflow, 36 in. [914] one side,

12 in. [304] the other. The side getting the greater clear-
ance is optional.

d. Overhead, 60 in. [1624] to assure proper condenser fan

operation.

e. Between units, control box side, 42 in. [1067] per NEC

(National Electrical Code).

f.

Between unit and ungrounded surfaces, control box
side, 36 in. [914] per NEC.

g. Between unit and block or concrete walls and other

grounded surfaces, control box side, 42 in. [1067] per
NEC.

h. Horizontal supply and return end, 0 inches.

6. With the exception of the clearance for the condenser coil

and combustion side as stated in notes 5a, b and c, a
removable fence or barricade requires no clearance.

7. Units may be installed on combustible floors made from

wood or Class A, B, or C roof covering material if set on
base rail.

8. The vertical center of gravity is 1

′-7″ [483] for 008, 1′-11″

[584] for 012 and 014 up from the bottom of the base rail.

Fig. 6 — Base Unit Dimensions