0 commands, 1 output data format, Commands – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - EtherNet/IP Interface Option Installation and Programming Manual User Manual

Page 17

Advertising
background image

Commands 13

4.0

Commands

Commands are used by the master device to send and receive data from the interface
as integer or floating-point data. The master sends eight bytes in the output format
(used to write commands to the indicator) and reads eight bytes in the input format
(used to read data from the indicator).
Decimal Point Handling
Integer commands return no decimal point information to the master. For example, a
value of 750.1 displayed on the indicator is returned to the master as 7501. Floating
point commands support decimal point information with no special handling.

4.1 Output Data Format

To perform a command, the master uses the output command format to send four 16-
bit words to the interface. These four words contain the command and any parameters
necessary to execute it. The output command format is shown in Table 4-1.

See Section 4.1.1 for BYTE swapping parameters.

The contents of each output command format word are described below.
Command number
The number representing the indicator command is sent in the first word. Table 4-2
lists the commands that can be specified for indicators. Some commands may not be
available on all indicators.

A lockout feature that looks for any change in the output format data is
incorporated into the indicator receive mechanism to prevent inundation
by the same command (affected commands noted in Table 4-1).
Repeated commands must be separated by any other valid command/
parameter/value combination.

Word

Description

Word 1

Command number

Word 2

Parameter

Word 3

Value (MSW)

Word 4

Value (LSW)

Table 4-1. Output Data Format

Decimal

Hex

Command

0

0x000

Return Status and Weight (integer)

1

0x001

Display Channel

2

0x002

Display Gross Weight

3

0x003

Display Net Weight

9

0x009

Gross/Net key press (toggle)

10

0x00A

Zero (see note)

11

0x00B

Display Tare (see note)

12

0x00C

Enter Tare (see note)

13

0x00D

Acquire Tare (see note)

14

0x00E

Clear Tare (see note)

Table 4-2. Remote Commands