Return Gross as Integer

Command: 32, 0x020
Parameter: Scale number

Command 32 returns the gross weight value for the specified scale as an integer.
Return Net as Integer

Command: 33, 0x021
Parameter: Scale number

Command 33 returns the net weight value for the specified scale as an integer.
Return Tare as Integer

Command: 34, 0x022
Parameter: Scale number

Command 34 returns the tare weight value for the specified scale as an integer.
Return Current Display as Integer

Command: 37, 0x025
Parameter: Scale number

Command 37 returns the weight value for the specified scale as currently displayed.
This may include gross, net, tare, or accumulator values, as enabled.
Return Accumulator as Integer

Command: 38, 0x026
Parameter: Scale number

Command 38 returns the accumulator value for the specified scale. This command is
only valid if the accumulator for the specified scale is enabled.
Set Batching State

Command: 95, 0x05F
Parameter: State (0 = off; 1 = auto; 2 = manual)

Command 95 sets the batching (BATCHNG) parameter. Indicator status is returned
with the current weight for the last scale specified.
Batch Start

Command: 96, 0x060
Parameter: Scale number

Command 96 starts a batch program from the current step after a stop, pause, or reset.
Batch status is returned with the current weight for the specified scale.
Batch Pause

Command: 97, 0x061
Parameter: Scale number

Command 97 pauses a batch program at the current step. Batch status is returned with
the current weight for the specified scale.
Batch Reset

Command: 98, 0x062
Parameter: Scale number

Command 98 stops a batch program and resets it to the first batch step. Batch status is
returned with the current weight for the specified scale.
Batch Status

Command: 99, 0x063
Parameter: Scale number

Command 99 returns the status of a batch. Batch status is returned with the current
weight for the specified scale.