10.2 Regulatory Mode Functions

The function of the front panel

TARE

and

ZERO

keys depends on the value specified for the REGULAT

parameter on the FEATURE menu. Table 10-4 describes the function of these keys for the NTEP, CANADA,
OIML, and NONE regulatory modes.

TARE

and

ZERO

key functions are configurable when the REGULAT mode

is set to INDUST (see Table 10-5 on page 104).

Table 10-5 lists the subparameters available when configuring a scale using INDUST mode. The table includes
the default values of the INDUST subparameters and the effective (not configurable) values used by the NTEP,
CANADA, OIML, and NONE regulatory modes.

REGULAT

Parameter Value

Weight on Scale

Tare in System

Front Panel Key Function

TARE

ZERO

NTEP

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

TARE

CANADA

zero or negative

no

no action

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

no action

OIML

zero or negative

no

no action

ZERO

yes

CLEAR TARE

ZERO and CLEAR TARE

positive

no

TARE

ZERO

yes

TARE

ZERO and CLEAR TARE if

weight is within ZRANGE.

No action if weight is outside of

ZRANGE

NONE

zero or negative

no

TARE

ZERO

yes

CLEAR TARE

positive

no

TARE

yes

CLEAR TARE

Table 10-4. TARE and ZERO Key Functions for REGULAT Parameter Settings

REGULAT / INDUST Parameter

REGULAT Mode

Parameter Name

Text Prompt

INDUST

NTEP

CANADA

OIML

NONE

SNPSHOT

Display or Scale weight source

DISPLAY

DISPLAY

DISPLAY

DISPLAY

SCALE

HTARE

Allow tare in display hold

NO

NO

NO

NO

YES

ZTARE

Remove tare on ZERO

NO

NO

NO

YES

NO

KTARE

Always allow keyed tare

YES

YES

NO

YES

YES

MTARE

Multiple tare action

REPLACE

REPLACE

NOTHING

REPLACE

REMOVE

NTARE

Allow negative tare

NO

NO

NO

NO

YES

CTARE

Allow CLEAR key to clear
tare/accumulator

YES

YES

NO

NO

YES

CHILDZT

Clear child scales individually

NO

NO

NO

NO

NO

Table 10-5. REGULAT / INDUST Mode Parameters, Comparison with Effective Values of Other Modes