6

920i

Installation Manual

1.5

Summary of Changes

Changes to recent editions of this manual are listed
below:

Version 3.07

Support has been added for the dual-channel
analog output card (PN 103138) and the
ControlNet interface card (PN 103136).

New OVRBASE parameter, on the
REGULAT submenu of the FEATURE menu,
allows specification of calibrated or scale zero
as the base for overload calculation. See
page 43 for more information.

A new top-level menu, FLDBUS, is now
shown if a DeviceNet, Profibus, EtherNet/IP,
or ControlNet is installed.The two parameters
u n d e r t h e F L D B U S m e n u a l l o w b y t e
swapping to be enabled (SWAP parameter)
and for the transfer size of the swapped bytes
t o b e s p e c i f i e d ( D ATA S I Z E ) . S e e
S e c t i o n 3 . 2 . 8 o n p a g e 4 9 f o r m o r e
information.

The default A/D sample rate (SMPRAT
parameter on the SCALES menu) has been
changed from 120 to 30 Hz.

The KEXIT command has been removed and
r e p l a c e d w i t h K S AV E E X I T. ( S e e
Section Table 9-1. on page 84.)

Error codes returned on the XE serial
command have been updated (see Table 10-3
on page 103).

Version 3.05-3.06

Support for local/remote indicator configurations
provides function equivalent to a legal-for-trade
remote display with keypad for truck scale and
similar applications. See Section 10.5 on
page 106
for more information.

The description for setting rate of change (ROC)
parameters has been changed. See Table 3-3 on
page 27
for details.

New values have been added to the STREAM
parameter on the SERIAL menu to allow
streaming of keypad events to another indicator
(4KEYS, KEYPAD) and, for the local/remote
function, to send the complete display image
(DISPLAY). See Section 3.2.2 for more
information.

Reprinting of any previous print transaction is
now supported by the alibi feature. The feature is
enabled using the ALIBI parameter on the
FEATURE menu; print transactions can be
recalled by assigning an

Alibi

softkey, also

configured using the FEATURE menu (see
Section 3.2.3 on page 38).

New IMAGE parameter on the FEATURE menu
a l l o w s i n v e r s i o n o f t h e d i s p l a y i m a g e
(blue-on-white or white-on-blue) for support of
the outdoor display option. See Section 3.2.3.

Display and printing of audit trail information is
described in Section 10.11 on page 116.

Version 3.00

The desktop model of the

920i

has been

discontinued. Drawings and parts lists for the
desktop model have been removed from this
manual.

Added support for multi-range and
multi-interval scale configurations.

Zero tracking, zero range, and motion band
parameters (SCALES menu) have been
changed to allow numeric values.

Added peak hold function to SCALES menu.

Added last zero and temporary zero functions
to calibration menus to allow recalibration
based on previous zero values.

Enhanced print formatting with addition of
audit format and twenty auxiliary formats.

The SERIAL menu has been restructured to
provide additional parameters for configuring
RS-485 communications. See Figure 3-10 on
page 35.

A new digital input count (DINCNT) setpoint,
used to count digital input pulses, has been
added to the supported setpoint kinds. See
Section 8.0 on page 65.

A SENSE parameter has been added to
optionally invert the value of setpoint digital
outputs. See Section 8.0 on page 65.

TRIGGER (digital output trigger) has been
added as a selection under the DIG I/O menu
(see Section 3.2.6 on page 46) for custom
applications.

Support has been added for EtherNet/IP and
analog input/thermocouple option cards.