Serial Commands

91

Command

Description

Values

GFMT.FMT
GFMT.PORT

Gross demand print format string

For .PORT commands, specify the port number as PORTxx (no
leading zero). For example: GFMT.PORT=PORT3.

For AUXFMT.FMT commands, specify the auxiliary format number
(1—20) as AUXFMTxx (no leading zero). For example:
AUX8FMT=GROSS<G><NL2>…

See Section 6.0 on page 57 for information about demand print
format strings.

See the

iQUBE

Installation Manual, PN 77224, for more information

about alert formats.

NFMT.FMT
NFMT.PORT

Net demand print format string

ACC.FMT
ACC.PORT

Accumulator print format string

SPFMT.FMT
SPFMT.PORT

Setpoint print format string

TRWIN.FMT
TRWIN.PORT

Truck weigh-in print format string

TRWOUT.FMT
TRWOUT.PORT

Truck weigh-out print format string

TR.FMT
TR.PORT

Truck register print format string

ALERT.FMT
ALERT.PORT

Alert format string

HDRFMT1
HDRFMT2

Ticket header format strings

AUXFMTxx.FMT
AUXFMTxx.PORT

Auxiliary ticket format

AUD.PORT

Audit trail port

WDGT#n

Display widget

widget_number

See Section 9.2 on page 96 for widget programming information.

WDGT.CLR

Clear widgets

Table 9-7. PFORMT Serial Commands

Command

Description

Values

DON.b#s

Set digital output on (active) at bit b, slot s.

DOFF.b#s

Set digital output off (inactive) at bit b, slot s.

DIO.b#s

Digital input function

OFF, INPUT, OUTPUT, PROGIN, ZERO, NT/GRS,
TARE, UNITS, PRINT, ACCUM, SETPNT,
TIMDATE, ESC, CLEAR, DSPTAR, IDKEY,
KEY0–KEY9, KEYDP, ENTER, NAVUP, NAVDN,
NAVLFT, NAVRGT, KBDLOC, HOLD, BATRUN,
BATSTRT, BATPAUS, BATRESET, BATSTOP,
CLRCN, GROSS, NET, PRIM, SEC, CLRTAR,
CLRACC, TRIGGER

DIO.TRIG_SLOT.b#s

Trigger output slot

NONE, SLOT3

DIO.TRIG_PARAM.b#s

Trigger output parameter

value

Digital inputs and outputs are specified by bit number (b) and slot number (s)

Table 9-8. DIG I/O Serial Commands