10.4 Serial Scale Interface

Serial ports 3 through 32 can be configured for serial
scale input. The serial scale function allows other
scale indicators to send gross, net, or tare weight data
to the

920i

. Once a serial port has been configured to

accept scale data, the data format can be customized
to match the data stream sent by that indicator.

To configure a serial scale, do the following:

1. Under the SERIAL menu, set the INPUT

parameter for the selected port to SCALE
(legal-for-trade serial scale) or INDUST
(industrial serial scale).

2. Return to the SCALES menu. Under CONFIG,

drop down and select the serial port. If the serial
scale is not shown, press the

Change Type

softkey to select available serial scales, then use
the navigational keys to select the serial scale.
Press

Add

to move the scale to the righthand

column, the press

Done

.

3. Under the SERIAL menu, return to the selected

p o r t a n d s e t t h e f o r m a t u n d e r t h e S F M T
parameter to match the format sent by the serial
scale.

The default serial scale format is:

<2><P><W7.><U><M><S><CR><LF>

where:

<2>

STX character

<P>

Polarity

<W7.>

Seven characters of net data with decimal point

<M>

Mode

<U>

Units

<S>

Status

<CR>

Carriage return

<LF>

Line feed

NOTE:

Industrial serial scales (INDUST) do not require

the

<M>

,

<U>

, and

<S>

identifiers. However, the units and

number of decimal places must be specified. Units can
be selected from the FORMAT menu; decimal places
should be indicated on the w-spec identifier. For
example, a seven-digit weight requiring two decimal
places should be specified as

<W7.2>

rather than

<W7.>

.

See Section 10.6 for more information about stream
formatting and format identifiers.

iRev

provides several preset scale formats within its

Stream Formatting function. Figure 10-1 shows one of
the

iRev

stream formatting displays.

Figure 10-1.

iRev Stream Formatting Display

10.5 Local/Remote Operation

For truck scale and similar applications, local/remote
support provides function equivalent to that of a
legal-for-trade remote display with keypad. Scale data
from the local indicator is also displayed at the remote
unit, and keypad input from the remote allows transactions
to be initiated from either the local or remote unit.

To configure for local/remote operation, first set up
the local scale (including softkey assignments, truck
mode, and database information, as required). Use the
SERIAL menu, serial commands, or

iRev

to set the

Local Unit serial parameters shown in Table 10-7.
Configure the remote indicator using the serial
parameters listed for the Remote Unit.

Serial

Configuration Parameter

Parameter Value

Local Unit

Remote Unit

EDP.INPUT#p

CMD

DISPLAY

EDP.STREAM#p

DISPLAY

KEYPAD

EDP.BAUD#p

115200 preferred; local and

remote values must match

EDP.ECHO#p

OFF

OFF

EDP.RESPONSE#p

ON

ON

In the listed serial commands, p represents the serial port
number.

Table 10-7. Local/Remote Configuration Parameters