5 summary of changes – Rice Lake 920i Installation Manual V4.0 User Manual

Page 11

Advertising
background image

Introduction

5

Option Cards

Table 1-4 lists the available

920i

option cards. Any of

the listed option cards can be installed in Slot 2 of the
CPU board or in any available slot of an attached
expansion board.

Table 1-4. Part Numbers for

920i Option Cards

Option Card

PN

Single-channel A/D card

68532

Dual-channel A/D card

68533

Single-channel analog output card

67602

Dual-channel analog output card

103138

Dual serial port expansion card

67604

24-channel digital I/O expansion card

67601

1MB NV RAM memory expansion card

67600

Pulse input card

67603

Ethernet communications card

71986

EtherNet/IP interface card

87803

DeviceNet interface card

68541

Allen-Bradley Remote I/O interface card

68539

Profibus DP interface card

68540

ControlNet interface card

103136

Analog input card with thermocouple input

87697

Expansion Boards

Table 1-5 lists the expansion boards available for the
panel mount and wall mount enclosures. The panel
mount enclosure can accommodate a single 2-card
expansion board; the wall mount enclosure supports
either a 2-card or a 6-card expansion board. Any of
the available option cards can be installed in any
available expansion board slot.

A second two- or six-card expansion board can also be
connected to the

920i

, providing up to 14 option card

slots. Consult factory for details. See Section 2.5 on
page 13 for
detailed information about slot and serial
port assignments for expanded system configurations.

Table 1-5. Part Numbers for

920i Expansion Boards

Expansion Board

PN

Two-card expansion board for panel mount
enclosure, slots 3–4. Includes 2-inch, 34-pin
ribbon cable and power supply cable.

71743

Two-card expansion board for wall mount
enclosure, slots 3–4. Includes 24-inch, 34-pin
ribbon cable and power supply cable.

69782

Six-card expansion board for wall mount
enclosure, slots 3–8. Includes 16-inch, 34-pin
ribbon cable and power supply cable.

69783

Relay Options

8-, 16-, and 24-channel relay racks are available for all

920i

systems. Relays can be installed internally in the

wall mount enclosure; all other models require an
external enclosure for the relays. Consult factory for
details.

DC Power Supplies

Two DC power supplies are available for mobile

920i

applications:

PN 97474, 9–36 VDC supply
PN 99480, 10–60 VDC supply

Consult factory for more information.

Outdoor Display

An optional display, PN 100759, is available for
applications requiring use of the

920i

in bright, sunlit

environments. Consult factory for details.

1.5

Summary of Changes

Changes to recent editions of this manual are listed
below:

Version 4.0

Added support for

iQUBE

2

and removed

support for

iQUBE

.

NOTE: Version 4.0 requires Rev E CPU board or newer.

Version 3.13

Added a new value <AN> to the Print
Formatting section of the manual (see Section
6.1, Table 6-1 on page 60).

Corrected comparisons to reduce the number
of power-up calibrations counted by Audit
Trail.

Added the speed-up of loading a user program
by only erasing needed memory blocks.

Version 3.10

Error Recovery - version 3.10.00 of the 920i
now has a very sophisticated error recovery
for the battery backed NVRAM. when a Save
and Exit is performed after a Configuration
and Calibration is performed, there is a copy
of the NVRAM that is stored in Flash for
future recovery. If the 920i is powered off at
any time and the battery is not at peak
performance, the NVRAM could come up
with corrupted data. The next time the 920i is
powered up, the NVRAM is tested for a
correct CRC checksum. If this is bad, there
will be a special screen displayed showing the
corrupt locations with directions to press
ENTER to continue. The core will rewrite to
NVRAM using the last copy of the last Save
and Exit. At this time Date and Time are also

Advertising