Rice Lake 920i Installation Manual V4.0 User Manual

Page 98

Advertising
background image

92

920i

Installation Manual

Command

Description

Values

SP.KIND#n

Setpoint kind

OFF, GROSS, NET, –GROSS, –NET, ACCUM, ROC, +REL, –REL,
%REL, RESREL, PAUSE, DELAY, WAITSS, COUNTER, AUTOJOG,
COZ, INMOTON, INRANGE, BATCHPR, TIMER, CONCUR, DIGIN,
AVG, TOD, DELTA, CHWEI, PLSCNT, PLSRAT, ALWAYS, NEVER,
DINCNT

SP.VALUE#n

Setpoint value

number

SP.SOURCE#n

Source scale

SCALE1, SCALE2, SCALE3…SCALEx

SP.COAST#n

Pulse counter coast

number

SP.TRIP#n

Trip

HIGHER, LOWER, INBAND, OUTBAND

SP.BANDVAL#n

Band value

number

SP.HYSTER#n

Hysteresis

number

SP.PREACT#n

Preact type

OFF, ON, LEARN, FLOW

SP.PREVAL#n

Preact value

number

SP.PREADJ#n

Preact adjustment percentage

number

SP.PRESTAB#n

Preact learn stability

number

SP.PCOUNT#n

Preact learn interval

number

SP.TOLBAND#n

Target tolerance

number

SP.TOLCNT#n

Tolerance count

number

SP.BATCH#n

Batch step enable

OFF, ON

SP.CLRACCM#n

Clear accumulator enable

OFF, ON

SP.CLRTARE#n

Clear tare enable

OFF, ON

SP.PSHACCM#n

Push accumulate

OFF, ON, ONQUIET

SP.PSHPRINT#n

Push print

OFF, ON, WAITSS

SP.PSHTARE#n

Push tare

OFF, ON

SP.ALARM#n

Alarm enable

OFF, ON

SP.NAME#n

Setpoint name number

NONE, 1–60

SP.ACCESS#n

Setpoint access

OFF, ON, HIDE

SP.DSLOT#n

Digital output slot

NONE, SLOTx

SP.DIGOUT#n

Digital output

BITx

SP.SENSE#n

Digital output sense

NORMAL, INVERT

SP.BRANCH#n

Branch destination

0, 1-100

SP.RELNUM#n

Relative setpoint number

1–100

SP.START#n

Starting setpoint

1–100

SP.END#n

Ending setpoint

1–100

SP.DISLOT#n

Digital input slot

NONE, SLOTx

SP.MASK#n

Digital input mask

number

SP.NSAMPLE#n

Number of samples

number

SP.TIME#n

Trip time

hhmm

SP.DURATION#n

Trip duration

hhmmss

SP.VUNDER#n

Underrange value

number

SP.VOVER#n

Overrange value

number

SP.DUNDER#n

Underrange digital output

BITx

Table 9-6. SETPNTS Serial Commands