Setpoints

83

8.3

Batch Operations

Softkeys can be configured to allow operator control
of batch operations from the

920i

front panel (see

Figure 8-10), Softkeys can be configured using

iRev 4

,

serial commands, or the FEATURE menu (see
Section 3.2.3 on page 39).

Figure 8-10. Batching Softkeys

Setpoint

Display or change assigned setpoints.

Batch Start

Starts batch process.

Batch Pause

Pauses an active batch and turns off
a l l d i g i t a l o u t p u t s e x c e p t t h o s e
associated with concurrent and timer
setpoints. Processing is suspended
until

Batch Start

is pressed again.

Pressing

Batch Start

resumes the

batch and re-energizes all digital
outputs turned off by the

Batch Pause.

Batch Reset

Stops and resets an active batch to the
beginning of the process.

Batch Stop

Stops an active batch and turns off all
associated digital outputs.

Warning

To prevent personal injury and equipment
damage, software-based interrupts must
always be supplemented by emergency stop
switches and other safety devices necessary
for the application.

Batching Switch

The batching switch option, PN 19369, comes as a
complete unit in an FRP enclosure, with legend plate,
locking stop switch (mushroom button), and a run/
start/abort 3-way switch.

Both switches are wired into the indicator’s digital I/O
terminal strip as shown in Figure 8-12. Each switch
uses a separate digital input.

Once cables and switches have been connected to the
indicator, use the setup switch to place the indicator in
setup mode. Use the DIG I/O menu (see Section 3.2.6
on page 47
) to configure digital input and output
functions.

Figure 8-11. Batching Switch

When configuration is complete, exit setup mode.
Initialize the batch by turning the 3-way switch to

ABORT

, then unlock the STOP button (the STOP

button must be in the OUT position to allow the batch
process to run). The batching switch is now ready to
use.

If no digital input is assigned to
BATRUN, batching proceeds as if
BATRUN were always on: the batch will

start when the 3-way switch is turned to RUN, but the STOP
mushroom button will not function.

RED

WHITE

BLACK

RED

BLACK

STOP/START MUSHROOM SWITCH

ABORT/RUN/START SWITCH

A
B
O
R
T

S
T
A
R
T

3

4

1

2

NO

NC

NC

NO

NO

J2

+5VDC

GND

DIO1

DIO2

DIO

3

DIO4

DIGITAL I/O

1

2

4

5

6

3

CPU BOARD

3

4

1

2

3

4

Figure 8-12. Batching Switch Wiring Diagram Example