Rice Lake 920i Installation Manual V4.0 User Manual

Page 36

Advertising
background image

30

920i

Installation Manual

DECPNT

8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
888888.8

Decimal point location. Determines the location of the decimal point or dummy zeros in the
display.

DSPDIV

1D
2D
5D

Display divisions. Selects the minimum division size for the ROC units displayed weight.

MULT

1.0
0.000001–
9999999

Multiplier. Specifies the conversion factor by which the primary units are multiplied by to
obtain the displayed rate of change units.

See Section 10.10 on page 117 for information about conversion factors.

UNITS

SEC
MIN
HOUR

Rate-of-change units.

INTERVL

10
1–100

Update interval. Specifies the number of refreshes over which the rate-of-change is
calculated.

For example, with REFRESH set to 0.1 second and INTERVL at 60, each weight value takes
6 seconds (0.1 * 60) to be flushed from the ROC data.

REFRESH

0.1
0.1–60

Refresh interval. Specifies the number of seconds between rate-of-change samples.

SCALES Menu, FORMAT Submenu, SPLIT = OFF

Parameter

Choices

Description

Table 3-3. SCALES Menu, FORMAT Submenu Parameters, SPLIT = OFF (Continued)

Advertising