Wiring the junction box – Rice Lake BCi Belt Scale - Installation & Operation Manual Version 2.00 User Manual

Page 23

Advertising
background image

BCi

Installation & Operation Manual - Integrator Hardware Installation

17

Wiring the Junction Box

The four channel TuffSeal JB4SS has been designed to connect and trim up to four load cells per board.
However, it is possible to use this junction box with other combinations.

Run the load cell cables from the load cells through the channels on the scale carriage over to the junction box.

Figure 2-6. Route Load Cell Cable From Load Cell to Junction Box

3. Open the cover to the junction box to expose the interior.

4. Wire the junction box by running the load cell cable inside of the junction box.

Figure 2-7. Junction Box Interior

Use the following table to wire the load cell cables.

Wire Color

Signal

Red

+EX

Black

-EX

Green

+SIG

White

-SIG

Silver Braid

SHIELD

Table 2-1. Load Cell Wiring

Run load cell
c a b l e
t h r o u g h
s c a l e
c a r r i a g e
channel