Wiring the Junction Box
The four channel TuffSeal JB4SS has been designed to connect and trim up to four load cells per board.
However, it is possible to use this junction box with other combinations.
Run the load cell cables from the load cells through the channels on the scale carriage over to the junction box.
Figure 2-6. Route Load Cell Cable From Load Cell to Junction Box
3. Open the cover to the junction box to expose the interior.
4. Wire the junction box by running the load cell cable inside of the junction box.
Figure 2-7. Junction Box Interior
Use the following table to wire the load cell cables.
Wire Color
Signal
Red
+EX
Black
-EX
Green
+SIG
White
-SIG
Silver Braid
SHIELD
Table 2-1. Load Cell Wiring