2 diagnostics, 3 reset totalizer, 4 start fill – Rice Lake BCi Belt Scale - Installation & Operation Manual Version 2.00 User Manual

Page 60: 2 diagnostics 6.3 reset totalizer 6.4 start fill

Advertising
background image

54

BCi

Installation & Operation Manual

6.2

Diagnostics

Diagnostics checks the following parameters to ensure that the outputs are working properly. When pressing the

Diagnostics

softkey, the following screen is displayed.

Figure 6-3.

Press the

Exit

softkey to exit out of diagnostics.

6.3

Reset Totalizer

The operator has the option to clear the totalizer of all data. Select the

Reset Totalizer

softkey and the user is

prompted

Clear Totalizer

? Press

Yes

to clear the information or

No

to keep the entered information. If selecting Yes,

the screen prompt says that the

Totalizer has been reset

.

6.4

Start Fill

The

Start Fill

softkey starts the fill process and turns on the digital output until the target preact is met. Once the

target preact is met, the on-screen display changes to

Stop Fill

which turns off the digital output and gives the

operator the

Re-Start

or

Abort

softkey.

Pressing

Re-Start

will resume the fill process.

Pressing

Abort

will halt the filling process and returns the integrator to normal operation.

SCALE #1

11/23/2011

08:13AM

mV Input

PPS

Analog Out

A/D Counts

0.710

34

3.0

167.8

Exit =>

235

Master Total

Advertising