12 rate count by, 13 totalizer count by, 14 load display units – Rice Lake BCi Belt Scale - Installation & Operation Manual Version 2.00 User Manual

Page 47: 15 load count by, 16 auto zero tracking (%), 17 auto zero tracking percentage, 18 dead band, T (metric tons) • lt (long ton) press the, Key on the integrator and a, Again to save that value

Advertising
background image

BCi

Installation & Operation Manual - Supervisor Mode Parameters

41

T (metric tons)

LT (long ton)

Press the

enter

key to toggle between the listed

choices above. The default rate display is TN/Hr.

4.12 Rate Count By

This parameter defines what county by and decimal
divisions the rate will be displayed. This is a value
that can be keyed in using the numeric keypad on the
display, 1, 2, 0.1, 0.01, etc. To change the rate count
by value, press the

enter

key on the integrator and a

rate count by prompt

appears. Using the numeric keypad

on the integrator, enter the value and press

enter

again

to save that value.

4.13 Totalizer Count By

This parameter is defined by what the count by and
decimal divisions the totalizers will be displayed. This
is a value that can be keyed in such as 1, 2, 0.1, 0.01,
erc. To change the totalizer count by value, press the

enter

key on the integrator and a

totalizer count by

prompt appears. Using the numeric keypad on the
integrator, enter the value and press

enter

again to save

that value.

4.14 Load Display Units

This parameter defines what weight units the belt
loading is displayed in. The selections are displayed in
the following units:

Lb - default

kg

Press the

enter

key to toggle between the listed

choices. The default load display unit is Lb.

4.15 Load Count By

This parameter is defined by what count by and
decimal divisions the load is to be displayed in. this is
a value that can be keyed in using the numeric keypad
on the BCi such as 1, 2, 0.1, 0.01, etc. To change the
load count by value, press the

enter

key on the

integrator and a

load count by

prompt appears. Using

the numeric keypad on the integrator, enter the value
and press

enter

again to save that value.

4.16 Auto Zero Tracking (%)

This is the percentage of full scale that zero tracking is
attempted. If the rate is larger than this value, the zero
tracking is turned off.

4.17 Auto Zero Tracking Percentage

This is the percentage of full scale that will zero a
track off.

4.18 Dead Band

The accumulator will only totalize the amount if the
rate is above the dead band value. Press the

enter

key

to add the dead band value and press

enter

again to

save that value.

End

SCALE #1

Home

Cancel

11/23/2011

08:13AM

Load Cell MV

Total LC Build

Rate Unit Time

Filter

Speed Unit Time

Fixed Speed

Unit of Measure

Unit of Rate

Rate Count By

Totalizer Count By

200.00

Min

10

Min

5.0

Ft

T

0.1

0.1

2.0000

Rate Count By

End

SCALE #1

Home

Cancel

11/23/2011

08:13AM

Load Cell MV

Total LC Build

Rate Unit Time

Filter

Speed Unit Time

Fixed Speed

Unit of Measure

Unit of Rate

Rate Count By

Totalizer Count By

200.00

Min

10

Min

5.0

Ft

T

0.1

0.1

2.0000

Totalizer Count By

End

SCALE #1

Home

Cancel

11/23/2011

08:13AM

Load Display Units

Load Count By

Auto Zero Tracking

Filter

Speed Unit Time

Fixed Speed

Unit of Measure

Unit of Rate

Rate Count By

Totalizer Count By

Lb

0.1

10

Min

5.0

Ft

T

0.1
0.1

0.1

Load Count By