44

BCi

Installation & Operation Manual

I/O NOTE: There are six onboard I/O
bits on the BCi integrator. Depending
on their use, the installer may need to

reconfigure the use to “

OUTPUT

” or “

PROGIN

”.

If the use is as a remote button supported by the BCi
software, the softkey will be

PROGRIN

. If it’s used as

one of the alarm bits, then

OUTPUT

is the setting.

4.42 Remote Print Input Bit

This parameter defines which digital input bit will
work the same as the Print key on the front of the BCi.

The default value for this parameter is: 4.

NOTE:

4.43 Print Output Port

This parameter defines which serial port the print
format will be sent from.

The default value for this parameter is: 0.

4.44 Print Format

This parameter defines the print format for the belt
scale integrator.

The default value for this parameter is:

TIME: <TI><NL>DATE: <DA><NL>MASTER TOTAL:

<MT><NL>RESET TOTAL:
<RT><NL>RATE: <R>

The default value for this parameter is: 0.0.

4.45 Stream Output Port

This parameter defines which serial port the stream
format will be sent from. The BCi will only stream if
this is set to a valid port with a value greater than zero.

The default value for this parameter is: 0.

4.46 Stream Format

This parameter defines the stream format for the belt
scale integrator.

The default value for this parameter is:

<R><NL>

4.47 Clear Totalizer with Print

Toggles between Yes and No

4.48 Remote Totalizer Reset Input

This parameter defines a digital input that can reset
the reset totalizer. This only affect the reset totalizer
and not the master totalizer. The master totalizer can
only be reset through the supervisor menu.

The default value of this parameter is: 0.Master
Totalizer Reset

To reset the Master Totalizer, press the

Master Totalizer

softkey from the Supervisor Mode to access this
parameter. The BCi prompts

Clear Master Totalizer

?

Press

Yes

to clear the totalizer or

No

to leave the

accumulated weight in the master totalizer.

4.49 Integrator Identification

The integrator ID can be an alpha-numeric string up to
8 characters.

Press the

enter

key and enter the identification ID and

press the

enter

key again to save this ID.

It can be used for printing or streaming information.

4.50 Preact Length

With this parameter, this value is used to dynamically
adjust the target value based on the rate of the belt
scale.

Enter the distance from the feed gate to the midpoint
of the weigh idler and the first dual idler. Enter the
preact length in feet and press the

enter

key to save

that parameter.

4.51 Enable Batching

Press On to enable batching When this is enabled,
system controls gates for filling applications.

When enabled, the operator will see

Start Fill

and

Target

Settings

softkeys on the display.

The default value is Off.

Note

No

SCALE #1

Yes

11/23/2011

08:13AM

Admin. Passcode (numeric)

Rate Unit Time

Speed Unit Time

Unit of Measure

Unit of Rate

Rate Count By

Totalizer Count By

Load Display Units

Load Count By

Calibration Weight

Hr

Sec

M

kg

0.1

0.1

lb

0.1

20.0

Clear Master Totalizer?