0 supervisor mode parameters, Supervisor mode parameters, Rate – Rice Lake BCi Belt Scale - Installation & Operation Manual Version 2.00 User Manual
Page 44
38
BCi
Installation & Operation Manual
4.0
Supervisor Mode Parameters
Various parameters can be set by using the
Supervisor Mode
softkey from the main menu.
NOTE: All parameters must be entered prior to calibrating the unit.
Figure 4-1. Supervisor Softkey Location
Press the
Supervisor Mode
softkey to access the following screen.
Figure 4-2. Supervisor Mode Parameters
Use the
up
and
down
arrow keys on the BCi to navigate the parameter list. Use the
enter
key to select the
parameter to edit. If the parameter is a value that can be entered, a user prompt will open. The operator can then
key in the new value and press
enter
to accept the new value. If the parameter has a list of available values, the
value will scroll through all available selections.
Supervisor
Mode
SCALE #1
Reset
Totalizer
Diagnostics
11/23/2011
08:13AM
Rate
Speed
Load
Totalizer
TN/Hr
Ft/Min
lb/ft
kg
293467.2
43.21
47.5
207467.8
S u p e r v i s o r M o d e
Softkey
Exit=>
SCALE #1
Master
Totalizer
Integrator
Calibration
Time/Date
Belt
Calibration
11/23/2011
08:13AM
Admin. Passcode (numeric)
Scale Capacity (Max Rate)
Load Cell MV
Total LC Build
Rate Unit Time
Filter
Speed Unit Time
Fixed Speed
Unit of Measure
Unit of Rate
500.00
3.00000
600
Hr
10
Min
0.00
Ft
TN
Use up and down arrows
on BCi to scroll through
various parameters.