4.0

Supervisor Mode Parameters

Various parameters can be set by using the

Supervisor Mode

softkey from the main menu.

NOTE: All parameters must be entered prior to calibrating the unit.

Figure 4-1. Supervisor Softkey Location

Press the

Supervisor Mode

softkey to access the following screen.

Figure 4-2. Supervisor Mode Parameters

Use the

up

and

down

arrow keys on the BCi to navigate the parameter list. Use the

enter

key to select the

parameter to edit. If the parameter is a value that can be entered, a user prompt will open. The operator can then
key in the new value and press

enter

to accept the new value. If the parameter has a list of available values, the

value will scroll through all available selections.

Supervisor

Mode

SCALE #1

Reset

Totalizer

Diagnostics

11/23/2011

08:13AM

Rate

Speed

Load

Totalizer

TN/Hr

Ft/Min

lb/ft

kg

293467.2

43.21

47.5

207467.8

S u p e r v i s o r M o d e
Softkey

Exit=>

SCALE #1

Master

Totalizer

Integrator

Calibration

Time/Date

Belt

Calibration

11/23/2011

08:13AM

Admin. Passcode (numeric)

Scale Capacity (Max Rate)

Load Cell MV

Total LC Build

Rate Unit Time

Filter

Speed Unit Time

Fixed Speed

Unit of Measure

Unit of Rate

500.00

3.00000

600

Hr

10

Min

0.00

Ft

TN

Use up and down arrows
on BCi to scroll through
various parameters.