Pulse Input Card

Use the following procedure to install pulse input cards in

BCi

integrator:

1. Disconnect integrator from power source.

Disconnect power before removing integrator backplate.

2. Place integrator face-down on an antistatic work mat. Remove screws that hold the backplate to the

enclosure body.

Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD) when
working inside the integrator enclosure.

3. Carefully align the large option card connector with connector J5 or J6 on the

920i

CPU board. Press

down to seat the option card in the CPU board connector.

Use the screws and lockwashers provided in the option kit to secure the other end of the option card to the
threaded standoffs on the CPU board.

Figure 3-3. Pulse Input Card

4. Make connections to the option card as required.

5. Use cable ties to secure loose cables inside the enclosure. Once cabling is complete, position the

backplate over the enclosure and reinstall the backplate screws. Use the torque pattern shown in the
backplate torque graphic on the next page to prevent distorting the backplate gasket. Torque screws to 15
in-lb (1.7 N-m).

6. Ensure no excess cable is left inside the enclosure and tighten cord grips.

Wire Color

Function

Brown

+12 V

Black

Pulse In

Blue

Ground

Table 3-2. Speed Wheel Pulse Input Wiring Colors