9 comparator function – Rice Lake GF Series, A&D Weighing User Manual

Page 44

Advertising
background image

42

10-9 Comparator Function

The results of the comparison are indicated by HI OK LO on the display.

Operating conditions: No comparison

Comparison when the weighing data is stable or overloaded, excluding

“near zero”

Comparison when the weighing data is stable or overloaded, including

“near zero”

Continuous comparison, excluding “near zero”

Continuous comparison, including “near zero”

To compare, use:

Upper limit value and lower limit value

Reference value and tolerance value

Input method:

Digital input

Weighing input

Command input from a computer (Refer to “18. COMMANDS”.)

Note
"Near zero" means within

±10 digits of the minimum weighing value. For example, using a GF-2000

in gram mode, near zero is within

±0.10 g.

For the description of “Comparator mode (Cp fnc)”, refer to “10-3 Details of the Function Table”.

Setting example 1

(Continuous comparison, excluding “near zero”, reference value and tolerance value, digital input)

Selecting a comparator mode

1 Press and hold the SAMPLE key until ba5fnc of the function table is displayed.

2 Press the SAMPLE key several times to display Cp fnc .

3 Press the PRINT key.

4 Press the RE-ZERO key several times to display Cp 3 .

5 Press the SAMPLE key several times to display Cp in .

6 Press the RE-ZERO key several times to display Cp in 2 .

7 Press the PRINT key to store the selected mode.

Entering the reference and tolerance values

8

With Cp ref displayed, press the PRINT key. The current setting is displayed with all the
digits blinking.

When the current setting is not to be changed, press the PRINT or CAL key to proceed to

step 9.

When the current setting is to be changed, press the RE-ZERO key. Change the setting

using the following keys.

SAMPLE key

To select the digit to change the value.

RE-ZERO key

To change the value of the digit selected.

MODE key

To switch the polarity.

PRINT key

To store the new setting and go to step 9.

CAL key

To cancel the new setting and go to step 9.

Advertising