Configuration

9

3.1.3

Front Panel Configuration

The 390HE indicator can be configured using a series of menus accessed through the indicator front panel when

the indicator is in setup mode. Table 3-1 summarizes the functions of each of the main menus.

Figure 3-2. Front Panel Key Functions in Setup Mode

Four front panel keys are used as directional keys to navigate through the menus in setup mode (see Figure 3-2).

The

UNITS

( ) and

PRINT

( ) keys scroll left and right (horizontally) on the same menu level;

ZERO

( ) and

GROSS/NET

( ) move up and down (vertically) to different menu levels. The

TARE

key ( ) serves as an Enter

key for selecting parameter values within the menus. A label over each of these keys identifies the direction

provided by the key when navigating through the setup menus.

Menu

Menu Function

CONFIG

Configuration

Configure grads, zero tracking, zero range, motion band, overload, tare function, and digital
filtering parameters.

FORMAT

Format

Set format of primary and secondary units, display rate.

CALIBR

Calibration

Calibrate indicator. See Section 4.0 on page 20 for calibration procedures.

SERIAL

Serial

Configure serial port.

PROGRM

Program

Set power-up and standby modes, counting scale functions, regulatory mode, unit ID and
consecutive number values.

P FORMT

Print Format

Set print format used for gross, net, and counting scale tickets. See Section 7.0 on page 27
for more information.

VERSION

Version

Display installed software version number.

Table 3-1. 390HE Menu Summary

Switch between

primary and

secondary units

Send data to

serial port

Set gross weight

to zero

Switch between

gross, net, and

piece count mode

Acquire tare

NORMAL MODE KEY FUNCTIONS

T

MODE

ENTER

SAMPLE

PRINT

ZERO

GROSS

NET

TARE

UNITS

PRINT

B/N

Units

T