Digital Filtering

The 390HE uses averaged digital filtering to reduce the effect of vibration on weight readings. Adjustable

threshold and sensitivity functions allow quick settling by suspending filter averaging, allowing the weight

reading to jump to the new value. Figure 8-3 shows the digital filter parameters on the CONFIG menu.

Figure 8-3. Digital Filtering Parameters on the Configuration (CONFIG) Menu

Figure 8-4. Flow Diagram for 390HE Digital Filters

8.6.1

DIGFLx Parameters

The first three digital filtering parameters, DIGFL1,

DIGFL2, and DIGFL3, are configurable filter stages

that control the effect of a single A/D reading on the

displayed weight. The value assigned to each

parameter sets the number of readings received from

the preceding filter stage before averaging (see

Figure 8-4).
The overall filtering effect can be expressed by

multiplying the values assigned to the three filter

stages:

DIGFL1 x DIGFL2 x DIGFL3

For example, if the filters are configured as

DIGFL1=4, DIGFL2=8, DIGFL3=8, the overall

filtering effect is 256 (4 x 8 x 8). With this

configuration, each A/D reading has a 1-in-256 effect

on the displayed weight value. Setting the filters to 1

effectively disables digital filtering (1 x 1 x 1 = 1).

8.6.2

DFSENS and DFTHRH Parameters

The three digital filters can be used by themselves to

eliminate vibration effects, but heavy filtering also

increases settling time. The DFSENS (digital filter

sensitivity) and DFTHRH (digital filter threshold)

parameters can be used to temporarily override filter

averaging and improve settling time:

DFSENS specifies the number of consecutive

scale readings that must fall outside the filter

threshold (DFTHRH) before digital filtering

is suspended.

DFTHRH sets a threshold value, in display

divisions. When a specified number of

consecutive scale readings (DFSENS) fall

outside of this threshold, digital filtering is

suspended. Set DFTHRH to NONE to turn off

the filter override.

1

2

4

8

DIGFL1

32

16

64

1

2

4

8

DIGFL2

32

16

64

1

2

4

8

DIGFL3

32

16

64

8OUT

32OUT

16OUT

64OUT

DFSENS

DFTHRH

2OUT

128OUT

4OUT

2DD

NONE

5DD

20DD

10DD

50DD

200DD

100DD

250DD

DIGFL1= n1

DIGFL2= n2

DIGFL3= n3

3rd Stage

Filter Average

2nd Stage

Filter Average

1st Stage

Filter Average

Displayed

Value

n3

2nd Stage

Filter Averages

n2

1st Stage

Filter Averages

n1

A/D Readings