0 appendix, 1 error messages, 2 continuous output (stream) format – Rice Lake Survivor 390HE Hostile Environment Digital Indicator User Manual

Page 34

Advertising
background image

30

SURVIVOR 390HE Installation Manual

8.0

Appendix

8.1

Error Messages

The 390HE provides a number of front panel error messages to assist in problem diagnosis. Table 8-1 lists these

messages and their meanings.

8.2

Continuous Output (Stream) Format

Figure 8-1 shows the continuous output format sent to the 390HE serial port when the STREAM parameter

(SERIAL menu) is set to either LFT or INDUST.

Figure 8-1. Continuous Output Data Format

Error Message

Description

Solution

ADCERR

A/D not responding

Call Rice Lake Weighing Systems (RLWS) Service.

ADCKSM

A/D coefficient checksum error

CFCKSM

Configuration checksum error

Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells.

CNTERR

Count error; insufficient sample size

Increase sample size.

DSPERR

Display error

Call RLWS Service.

EEPERR

EEPROM write error

LCCKSM

Load cell calibration checksum error

Recalibrate load cells.

LCPERR

Load cell power failure

Call RLWS Service.

PFCKSM

Print format checksum error

Check print formats for errors.

RAMERR

RAM test failed

Call RLWS Service.

TARERR

EEPROM read error

Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells.

VIREE

EEPROM error

Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells and reconfigure indicator.

------

Overflow error

Weight value too large (> 999999) to be displayed or gross value
exceeds overload limit. Check configuration.

______

A/D underrange

Weight value too small (< –99999) to be displayed or A/D reading <
–2.5 mV. Check scale for binding or damage.

STNDBY

Standby mode

Press any key to return to operating mode.

Table 8-1. 390HE Error Messages

<STX> <POL> <wwwwwww> <UNIT> <G/N> <S> <TERM>

ASCII 02

decimal

Polarity:
<space > = Positive
<–> = Negative

Weight: 7 digits, right-justified, dummy
zeroes, decimal point with no leading
zeroes except for leading zero immediately
preceding the decimal point. Leading
zeroes transmitted as spaces.

L = pounds
K = kilograms
T = metric tons (T)
G = grams
<space > =

OZ, TN, NONE

G = Gross

N = Net

Status:
<space > = valid
I = Invalid
M = Motion
O = Over/under range

<CR> <LF>

or <CR>

Advertising