Specifications

Power

Line voltages

115 VAC

Frequency

50 or 60 Hz

Power Consumption

100 mA (using 4 x 350W load cells)

Analog Specifications

Full Scale Input Signal Up to 17 mV
Excitation Voltage

5

± 0.25 VDC,

4 x 350

Ω or 8 x 700Ω load cells

Sense Amplifier

Differential amplifier with

4- and 6-wire sensing

Analog Signal

Input Range

–2.5 mV/V – 22.5 mV/V

Sensitivity

0.3

μV/graduation minimum,

1.5

μV/grad recommended

Input Impedance

200 M

Ω, typical

Noise (ref to input)

0.3

μV p-p with digital filters at 4-4-4

Internal Resolution

2

20

(approx. 1 000 000) counts

Display Resolution

999 999 dd

TEST Menu

Function

Description

A/DTST

Display A/D test

Press and hold Enter key to display raw count from A/D converter.

ADOFFS

A/D offset calibration (–0.5 mv/V)

Read Caution! statement on page 36 before using this function. Press and hold the setup switch, then press the
Enter key to perform offset calibration.

ADGAIN

A/D gain calibration (+4.5 mv/V)

Read Caution! statement on page 36 before using this function. Press and hold the setup switch, then press the
Enter key to perform gain calibration.

DEFLT

Default parameters

Press and hold the setup switch, then press the Enter key to reset configuration and calibration parameters to
factory default values. This function is equivalent to using the RESETCONFIGURATION EDP command followed
by the RS (reset) EDP command.

PRTCFG

Print configuration

Press the Enter key to print the indicator configuration to the serial port. This function is equivalent to using the
DUMPALL EDP command.

Table 8-5. Test Menu Functions

<STX> <POL> <wwwwwww> <UNIT> <G/N> <S> <TERM>

ASCII 02

decimal

Polarity:
<space > = Positive
<–> = Negative

Weight: 7 digits, right-justified, dummy
zeroes, decimal point with no leading
zeroes except for leading zero immediately
preceding the decimal point. Leading
zeroes transmitted as spaces.

L = pounds
K = kilograms
T = metric tons (T)
G = grams
<space > =

OZ, TN, NONE

G = Gross

N = Net

Status:
<space > = valid
I = Invalid
M = Motion
O = Over/under range

<CR> <LF>

or <CR>