Introduction

1

About This Manual

This manual is intended for use by service technicians

responsible for installing and servicing 390HE digital

weight indicators.
Configuration and calibration of the indicator can be

accomplished using the indicator front panel keys, the
EDP command set, or the Revolution

configuration

utility. See Section 3.1 on page 8 for information

about configuration methods.

Some procedures described in this manual
require work inside the indicator enclosure.
These procedures are to be performed by
qualified service personnel only.

Authorized distributors and their employees

can view or download this manual from the

Rice Lake Weighing Systems distributor

site at

www.ricelake.com

.

The Operator Card included with this manual

provides basic operating instructions for users of the

390HE. Please leave the Operator Card with the

indicator when installation and configuration are

complete.

1.0

Introduction

The 390HE is a single-channel digital weight

indicator housed in a NEMA 4X fiberglass reinforced

polyester (FRP) enclosure. The indicator front panel

consists of a 1-inch (25 mm), six-digit, liquid crystal

(LCD) display and a five-button keypad. Features

include:

Drives up to four 350

Ω or eight 700Ω load

cells

Supports 4- and 6-wire load cell connections

Electronic data processing (EDP) port for full

duplex, RS-232 communications at up to

19200 bps

Piece count mode for basic parts counting

functions.

The 390HE is NTEP-certified for Classes III and III L

at 10,000 divisions.

See for detailed specifications.

1.1

Operating Modes

The 390HE has several modes of operation:

Normal (weighing) mode

Normal mode is the “production” mode of the

indicator. The indicator displays gross or net

weights as required, using the LCD annunciators

described in Section 1.3 on page 2 to indicate

scale status and the type of weight value

displayed. Once configuration is complete and a

legal seal is affixed to the back of the indicator,

the 390HE can operate only in normal mode.

Piece count mode

In piece count mode, the indicator display shows

the number of parts on the scale rather than the

weight of those parts. Piece count mode has two

submodes:

Count display mode displays the current parts

count and allows ticket printing using the

CFMT print format.

Sample acquisition mode is used to calibrate

the indicator for parts counting.

Operator access to piece count mode is disabled

when the indicator is shipped from the factory. See

Section 6.0 on page 26 for detailed information

about counting operations.

Setup mode

Most of the procedures described in this manual

require the indicator to be in setup mode,

including configuration and calibration.
To enter setup mode, open the enclosure and press

the setup switch mounted on the end of the

pushbutton switch board. The indicator display

changes to show the word

CONFIG

.

Test mode

Test mode provides a number of diagnostic

functions for the 390HE indicator. Like setup

mode, test mode is entered using the setup switch.

See Section 8.7 on page 36 for more information

about entering and using test mode.