420HE Installation Manual - Installation

7

2.3.1

Cable Grounding

Except for the power cord, all cables routed through the
cord grips should be grounded against the CPU
mounting plate. Do the following to ground shielded
cables:

Use the lockwashers, clamps, and kep nuts
provided in the parts kit to install grounding
clamps on the enclosure studs adjacent to cord
grips. Install grounding clamps only for cord grips
that will be used; do not tighten nuts.

Route cables through cord grips and grounding
clamps to determine cable lengths required to
reach cable connectors. Mark cables to remove
insulation and shield as described below:

For cables with foil shielding, strip insulation and
foil from the cable half an inch (15 mm) past the
grounding clamp (see Figure 2-2). Fo
ld the foil
shield back on the cable where the cable passes
through the clamp. Ensure silver (conductive) side
of foil is turned outward for contact with the
grounding clamp.

For cables with braided shielding, strip cable
insulation and braided shield from a point just
past the grounding clamp. Strip another half inch
(15 mm) of insulation only to expose the braid
where the cable passes through the clamp (see
Figure 2-2
).

For load cell cables, cut the shield wire just past
the grounding clamp. Shield wire function is
provided by contact between the cable shield and
the grounding clamp.

Route stripped cables through cord grips and
clamps. Ensure shields contact grounding clamps
as shown in Figure 2-2
. Tighten grounding clamp
nuts.

Finish installation using cable mounts and ties to
secure cables inside of indicator enclosure.

Cord grip

Insulated cable

Foil (silver side out)

Grounding clamp

Shield wir e (cut)

Length of foil before folding
back on cable insulation

Cut insulation here
for foil-shielded cables

Braid

Cut insulation here
for braided cables

NOTE: Install lockwashers

first, against backplate,
under grounding clamp

Figure 2-2. Grounding Clamp Attachment for Foil-Shielded

and Braided Cabling

C7

RESET

R2

C15

C20

C19

R5

MECCA

C3

+5A V

R1

C13

R16

LED2

GND

GD1

C1

F1

DI

2

DI

1

DFB2

TR1

TVS2

TVS3

TVS6

C33

C31

DO2 DO1

C10

C9

+5V

G2E

R25

C30

VR3

R6

C8

U7

C5

C6

U8

R15

U1

LED1

EDP/
RS-232

JP2

C65

U3

SW1

SETUP

C32

C2

XT1

DFB1

TR2

TVS1

TVS5

TVS4

+3. 3

R7

R4

C16

C4

DIGIN

1

J1

LOAD CELL

U2

D1

U19

U6

U9

SERIAL

1

9

1

1

2

8

1

1

Gn

d

20mA+

Gnd

TxD

Gnd

Gn

d

DI

2

EXC-

19

20

E XC+

SEN-

SEN+

SIG-

1

5

1

1

1

20mA-

RxD

RxD

TxD

DI

1

SIG+

Micr o-
pr ocesso

r

DISPLA

Y

DRIVERS

KEYPAD

CONNECTOR

ANALOG

OUTPUT

OPTION CARD

REMOTE

SETUP

SWITCH

DC INPUT

R9

R10

R11

R12

ANA

ME

M

AD

HB

J9

J10

U4

OFF TEST

A / D C O N V E R T E R

U10

U11

J2

J3

J4

J7

J8

J11

J12

JP1

J1

4

3

2

1

JP2

POS

1

POS

2

JP

1

POS

1

POS

2

DIGOUT

1

+5V

DO2

Gnd

DO1

J6

R46

R47

U14

JMP3

(Factory Only)

ON

OF F

KEYPAD

CONNECTOR

HE_J2

1
2

B1

+

Figure 2-3.

420HE CPU and Power Supply Board with Analog Output Option Card

Advertising