0 appendix, 1 error messages, 1 displayed error messages – Rice Lake SURVIVOR 420HE Hostile Environment - Installation Manual User Manual

Page 42: Appendix, Displayed error messages

Advertising
background image

38

420HE Installation Manual

7.0

Appendix

7.1

Error Messages

The

420HE

indicator provides a number of error messages. When an error occurs, the message is shown on the

indicator LED display. Error conditions can also be checked remotely by using the XE EDP command as described
in Section 7.1.2 on page 39.

7.1.1

Displayed Error Messages

The

420HE

provides a number of front panel error messages to assist in problem diagnosis. Table 7-1 lists these

messages and their meanings.

Table 7-1.

420HE Error Messages

Error Message

Description

Solution

E A/D

A/D physical error

Call Rice Lake Weighing Systems (RLWS) Service.

EEEROM

EEPROM physical error

EVIREE

Virgin EEPROM

Use TEST menu to perform DEFLT (restore defaults) procedure, then
recalibrate load cells.

EPCKSM

Parameter checksum error

EACKSM

A/D calibration checksum error

A/D converter requires recalibration. Call RLWS Service.

EFCKSM

Printer format checksum error

Call RLWS Service.

ELCKSM

Load cell calibration checksum error

Recalibrate load cells.

EIDATA

Internal RAM checksum error

Call RLWS Service.

E REF

A/D reference error

A/D converter requires recalibration. Call RLWS Service.

ERROR

Internal program error

Check configuration. Run XE command (see Section 7.1.2 on
page 39
) to determine error type.
Call RLWS Service if unable to clear error by cycling power or if error
recurs.

OVERFL

Overflow error

Weight value too large to be displayed.

------

Gross > overload limit

Gross value exceeds overload limit. Check configuration or signal
input level. Overload can be caused by input signal > 45 mV or
common mode voltage > 950 mV.

______

A/D underrange

A/D reading < –4 mV. Check scale for binding or damage.

RNGERR

GRADS > 100,000
WVAL > 100,000

Only shows up in Config mode.

Advertising