0 configuration, 1 configuration methods, 1 revolution configuration – Rice Lake SURVIVOR 420HE Hostile Environment - Installation Manual User Manual

Page 17: 2 edp command configuration, Configuration, Revolution, Edp command configuration

Advertising
background image

420HE Installation Manual - Configuration

13

3.0

Configuration

To configure the

420HE

indicator, the indicator must be

placed in setup mode. The setup switch is accessed by
opening the enclosure and pressing the setup switch.

When the indicator is placed in setup mode, the word

CONFIG

is shown on the display. The CONFIG menu is

the first of ten main menus used to configure the
indicator. Detailed descriptions of these menus are
given in Section 3.2 on page 15. When configuration is
complete, return to the CONFIG menu and press the
(

ZERO

) key to exit setup mode.

3.1

Configuration Methods

The

420HE

indicator can be configured by using the

front panel keys to navigate through a series of
configuration menus or by sending commands or
configuration data to the EDP port. Configuration
using the menus is described in Section 3.1.3 on
page 14.

Configuration using the EDP port can be accomplished
using either the EDP command set described in
Section 5.0 or the

Revolution

®

software.

3.1.1

Revolution

Configuration

The

Revolution

configuration utility provides the

preferred method for configuring the

420HE

indicator.

Revolution

runs on a personal computer to set

configuration parameters for the indicator. When

Revolution

configuration is complete, configuration

data is downloaded to the indicator.

Figure 3-1. Sample

Revolution Configuration Display

Revolution

supports both uploading and downloading

of indicator configuration data. This capability allows
configuration data to be retrieved from one indicator,
edited, then downloaded to another.

To use

Revolution

, do the following:

1. Install the

Revolution

module on an

IBM-compatible personal computer running
Windows

®

98 or later. Minimum system

requirements are 4MB of extended memory
and at least 5MB of available hard disk space.

2. With both indicator and PC powered off,

connect the PC serial port to the indicator EDP
port.

3. Power up the PC and the indicator. Use the

setup switch to place the indicator in setup
mode.

4. Start the

Revolution

program.

Figure 3-1 shows an example of one of the

Revolution

configuration displays.

Revolution

provides online help for each of its

configuration displays. Parameter descriptions
provided in this manual for front panel configuration
can also be used when configuring the indicator using

Revo lu t io n

: the interface is different, but the

parameters set are the same.

3.1.2

EDP Command Configuration

The EDP command set can be used to configure the

420HE

indicator using a personal computer, terminal,

or remote keyboard. Like

Revolution

, EDP command

configuration sends commands to the indicator EDP
port; unlike

Revolution

, EDP commands can be sent

using any external device capable of sending ASCII
characters over a serial connection.

EDP commands duplicate the functions available using
the indicator front panel and provide some functions
not otherwise available. EDP commands can be used to
simulate pressing front panel keys, to configure the
indicator, or to dump lists of parameter settings. See
Section 5.0 on page 29 for more information about
using the EDP command set.

Advertising