4 indicator operations, 1 toggle gross/net mode, 2 toggle units – Rice Lake SURVIVOR 420HE Hostile Environment - Installation Manual User Manual

Page 8: 3 zero scale, 4 acquire tare, 5 remove stored tare value, 6 set date, 7 set time, Toggle gross/net mode, Toggle units

Advertising
background image

4

420HE Installation Manual

Table 1-1 shows which annunciators are used for all combinations of configured primary and secondary units. For
example:

If the primary unit is pounds (lb) and the secondary unit is kilograms (kg), the

lb

LED is lit for primary

units,

kg

for secondary units.

If the primary unit is pounds (lb) and the secondary unit is short tons (tn), the

lb

LED is lit for primary

units,

kg

for secondary units. There is not an LED for short tons, so the

kg

LED is used as the secondary

units annunciator.

If the primary unit is short tons (tn) and the secondary unit is pounds (lb), the

lb

LED is lit for primary units

(tn), and

kg

is lit for secondary units (lb). Because there is no LED for short tons, the

lb

and

kg

LEDs are

used as primary and secondary units annunciators.

See Section 3.2.2 on page 17 for more information about configuring primary and secondary display units.

Table 1-1. Units Annunciators, Showing Primary / Secondary LEDs Used for All Configurations

Primary Unit

Secondary Unit

lb

kg

oz

g

tn

t

none

lb

lb / lb

lb / kg

lb / oz

lb / g

lb / kg

kg

kg / lb

kg / kg

kg / oz

kg / g

lb / kg

oz

oz / lb

oz / kg

oz / oz

oz / g

oz / kg

g

g / lb

g / kg

g / oz

g / g

g / kg

tn

lb / kg

lb / kg

lb / oz

lb / g

lb / lb

lb / kg

lb / kg

t

lb / kg

lb / lb

lb / kg

none

lb / kg

lb / kg

lb / lb

1.4

Indicator Operations

Basic

420HE

operations are summarized below.

1.4.1

Toggle Gross/Net Mode

Press the

GROSS/NET

key to switch the display mode

from gross to net, or from net to gross. If a tare value
has been entered or acquired, the net value is the gross
weight minus the tare.

Gross mode is shown by the

Gross

annunciator; net

mode is shown by the

Net

annunciator.

1.4.2

Toggle Units

Press the

UNITS

key to switch between primary and

secondary units. The appropriate units LED under the
display is lit.

1.4.3

Zero Scale

1. In gross mode, remove all weight from the

scale and wait for the standstill annunciator
(

).

2. Press the

ZERO

key. The center of zero (

)

annunciator lights to indicate the scale is
zeroed.

1.4.4

Acquire Tare

1. Place container on scale and wait for the

standstill annunciator (

).

2. Press the

TARE

key to acquire the tare weight

of the container. Net weight is displayed and
net annunciator is lit.

1.4.5

Remove Stored Tare Value

1. Remove all weight from the scale and wait for

the standstill annunciator (

).

2. Press the

TARE

key. The

Gross

annunciator is

lit.

1.4.6

Set Date

In front panel setup mode use the arrow keys to toggle
to

DATE

. Press

DOWN

or

ENTER

to enter the date in the

format configured for the indicator. See Figure 1-2 5.

1.4.7

Set Time

In front panel setup mode use the arrow keys to toggle
to

TIME

. Press

DOWN

or

ENTER

to enter the time in

24-hour format, then press the

ENTE R

key. See

Figure 1-2 5.