5 program menu, Program menu – Rice Lake SURVIVOR 420HE Hostile Environment - Installation Manual User Manual

Page 25

Advertising
background image

420HE Installation Manual - Configuration

21

3.2.5

Program Menu

XXXXXXX

XXXXXXX

PWRUPM

GO

OIML

REGULA

000000

number

CONSNU

DELAY

SETPNT

PROGRM PFORMT

SERIAL

CALIBR

CONFIG FORMAT

000000

number

CONSTU

NTEP

CANADA

1

UID

VERS

DIGIN ALGOUT

DA TFMT

MMDDYY

DA TE

DDMMYY

YYMMDD

YYDDMM

DA TSEP

SLASH

DASH

SEMI

TIMFMT

12HOUR

TIME

24HOUR

TIMSEP

COLON

COMA

NONE

Figure 3-9. Program Menu

PROGRM Menu

Parameter

Choices

Description

Level 2 submenus

PWRUPM

GO
DELAY

Power up mode. In GO mode, the indicator goes into operation immediately after a brief power
up display test.

In DELAY mode, the indicator performs a power up display test, then enters a 30-second
warm up period. If no motion is detected during the warm up period, the indicator becomes
operational when the warm up period ends; if motion is detected, the delay timer is reset and
the warm up period repeated.

REGULA

NTEP
OIML
CANADA
NONE

Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.

OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero.
NONE allows tares to be acquired at any weight value.

OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no
load. NONE allows tares to be cleared at any weight value.

NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In
CANADA mode, the previous tare must be cleared before a new tare can be acquired.

NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as
long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be in
gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare.

UID

1

Specifies the unit identification number. Value specified can be any numeric value, up to six
digits.

DATE

DATFMT
DATSEP

Allows selection of date format and date separator. See Level three parameter for descriptions.

TIME

TIMFMT
TIMSEP

Allows selection of time format and separator. See level three parameter for descriptions.

CONSNU

000000
number

Consecutive numbering. Allows sequential numbering for print operations. The consecutive
number value is incremented following each print operation.

The initial value of this parameter is set to the start up value specified on the CONSTU
parameter. Changing either CONSTU or CONSNU immediately resets the consecutive number
used for printing.

CONSTU

000000
number

Consecutive number start up value. Specifies the initial consecutive number (CONSNU) value
used when the indicator is powered on.

Level 3 submenus

Table 3-6. Program Menu Parameters

Advertising