12 RL-TC Series Operation Manual

4.2 Description of Functions

Item

Set Value

Description

Bar graph display

1..b.G..

0

Disable

1

Enable

Limit function

2.SEL

0

Disable

1

Enable

D

is

pl

ay

ed

on

ly

w

hen

lim

it

func

ti

on

is

ac

ti

v

at

ed

Judgement

condition

21.Co.

1

Always judge (judges even when the balance is unstable)

2

Judge only when the balance is stable (does not judge
if the balance is unstable)

Judgement

range

22.L

0

Ranges beyond +5 graduation is judged (ranges +5
graduation or below, including negative ranges, are not
judged.)

1

The entire range is judged (the entire range, including
the negative, is judged).

Number of

points for

judgement

23.P

1

One-point setup (judges between OK and LO)

2

Upper-limit and lower-limit values are set up (judges
among HI, OK and LO).

Auto-zero

(zero-tracking)

3.A.O

0

Disable

This function automatically sets the zero point
exactly to zero to prevent slight deviations.

1

Enable

Auto power-off

4.A.P.

0

Disable (balance operates
continuously)

This function is available
only when the balance is
battery-operated.

1

Enable (balance powers off in
approximately three minutes)

Response speed

5.rE.

0

Measurement by consecutive weighings.

1

Fast

Slow

2

3

4

5

Stability parameters

6. 5.d.

1

Wide (mild)

Narrow (strict)

2

3

4

Interface

7. 1.F.

0

Disable input/output

1

Six-digit numeric format

2

Seven-digit numeric format

Setup of units of

measurement to be

displayed

Register selected

measuring units with

Function key.

1 01 [

g ]

2 14 [ ] (ct)

15 [ ] (oz)

16 [ ] (lb)

17 [ ] (ozt)

18 [ ] (dwt)

*

19 [ ►

Lower right

] (grain)

Items marked

are the default factory settings.

1~

5: default settings [

81.5.u

]~[

85.5.u.]

*