Final settings – Carrier PERFORMANCETSERIES EDGER THERMIDISTATT CONTROL TP-PRH-A User Manual

Page 46

Advertising
background image

46

non−programmable models, pressing the features button shall toggle the state of

the dry contact.
In a heat pump application, when the mode is set to “em heat” the auxiliary heat

will turn on for 3 minutes. The clock display will count down from 180 to 0

during this test.
TO TEST FAN
Fan button switches FAN icon between AUTO and On. While On is displayed,

G output will be energized, turning fan on. On some fan coils, fan continues to

operate for 90 sec after G signal is removed.

Final Settings

Be sure to press DONE to exit installer setup mode. If the system is to be left in

operation after installation is complete, use MODE button to select between

HEAT, COOL, or AUTO to provide desired operation of heating, cooling, or

auto.
On the programmable models, the default setpoints and programmed schedule

conform to the Energy Star

r requirements of the U.S. Department of Energy for

both heating and cooling. These provide energy saving temperature settings.

Refer to Table 1.

Table 1 – Energy Star Default Schedule

SCHEDULE

HEAT

COOL

Wake 6:00 AM

68

_F/20

_C

78

_F/26

_C

Day 8:00 AM

60

_F/16

_C

85

_F/29

_C

Evening 5:00 PM

68

_F/20

_C

78

_F/26

_C

Sleep 10:00 PM

60

_F/16

_C

82

_F/28

_C