Carrier PERFORMANCETSERIES EDGER THERMIDISTATT CONTROL TP-PRH-A User Manual

Page 78

Advertising
background image

78

Equipment Control Module

Furnace

Air Conditioner

Heat Stage 2

O/B W2

W2

Heat Stage 1

W/W1

W/W1

Cool Stage 1

Y1 / W2

Y1

Cool Stage 2

Y/Y2

Y/Y2

Y/Y2

Fan

G

G

24VAC Hot Heating

Rh

R

R

24VAC Hot Cooling

Rc

Dry Contact 1

D1

Dry Contact 2

D2

DHUM

24VAC Common

C

COM

C

Humidify

HUM

Outdoor Air Temp

OAT

Remote Room Sensor

RRS

OAT/RRS Com

SRTN

Outdoor Sensor *

Humidifier Solenoid

Valve *

Remote Room

Sensor *

Y1

* Indicates connection may not be required/available.

A09123

Fig. 32 − Variable Speed, Step Modulating, Multi−Stage and Single−Stage

Furnace with Two−Stage Air Conditioner