Carrier PERFORMANCETSERIES EDGER THERMIDISTATT CONTROL TP-PRH-A User Manual

Page 49

Advertising
background image

49

2. Auto Humidify

Thermidistat Control will automatically adjust the humidity setpoint

according to the outdoor temperature. As the outdoor temperature

decreases, the humidity setpoint also decreases. Settings ranging from 1 to

9, 1 being the lowest and 9 the highest, will be visible to the homeowner.

See Fig. 17 for outdoor temperature/indoor humidity relationship in auto

humidify mode.

3. Humidify Off

The humidify function can be turned off completely. This does not

require changing existing setpoints.

To Select Humidification (programmable)
Press the soft key below the humidify icon to bring up humidity select screen.

Humidify options are only available when in Heating mode. When system is in

AUTO mode, humidify options are available if the last system operation was a

call for heat.
To Select Humidification (non−programmable)
Press the features button twice. The first press displays the outdoor air

temperature and the second press displays the humidity value and humidify

target.
Pressing the mode button shall cycle through the available humidification

selections (Off, Humidify and Auto Humidify).
Additional Humidify Comments
The humidifier is actually turned on when humidity is 1% below setpoint and

turned off when it reaches 1% above setpoint. This built−in hysteresis prevents

humidify output from toggling on and off when humidity level is near setpoint.

Advertising