When changing Vacation settings, the soft keys are used to choose the selection

to be adjusted and the UP/DOWN buttons are used to change the setting.

Humidify setting may only be changed when heat mode is selected and

Dehumidify setting may only be changed when cool mode is selected.

Humidity Control Features

The various humidity control features of the Thermidistat Control are explained

below. They are grouped into 2 sections, humidification and dehumidification.

Instructions on how to select each feature are given at the end of each section.

Humidification

The Thermidistat Control directly connects to a standard 24VAC humidifier to

control humidification in the home. A humidify setpoint between 10 and 44% in

2% increments relative humidity is selected by the homeowner, or all

humidification can be turned off. When humidity in home drops below setpoint,

humidifier will be turned on to raise humidity level. Humidification can only

occur while in heating mode. See Table 2 for reference.

Table 2 – Humidification Selections

SELECTION

FAN DISPLAY

HUMIDIFY SETPOINT

DISPLAY

Normal Humidify

Blank

10-44

Auto Humidify

AUTO

1

Humidify Off

Blank

OF (Off)

1. Humidify

In normal humidify, humidifier will be on if there is humidity demand

and any heating equipment is on. This will include furnace, heat pump, or

auxiliary heat.