Carrier PERFORMANCETSERIES EDGER THERMIDISTATT CONTROL TP-PRH-A User Manual

Page 7

Advertising
background image

7

Remote Indoor Temperature Sensor

A remote temperature sensor may be used with the programmable model, where

it is desirable to install the Thermidistat Control in a limited access location while

measuring the temperature in the living space. The remote room sensor may be

used as a stand alone or average with local sensor.

Two−Piece Thermidistat Control Configuration

The Performance Series Thermidistat Control can be installed in one of two

configurations. The control may be installed as a single−piece Thermidistat

Control or it may be split into two pieces and mounted in separate locations. As

a single−piece unit, all required wiring must be brought to the Equipment

Control Module for connection to the terminal strip. In two−piece configuration,

the Display Module can be mounted in the living space while the Equipment

Control Module may be mounted near the indoor furnace or fan coil. Connection

from the Display Module to the Equipment Control Module requires only two

wires. All other control wires are connected to the Equipment Control Module

from the HVAC equipment. This configuration results in a slimmer display and

locates the Equipment Control Module containing the switching relays away

from the main living space where relay clicking will not be heard.
The model numbers on the Display Module and the Equipment Control Module

(ECM) must match or unpredictable results may occur.
Two−wire pigtail replacement part number is TX−2WR05.

Wiring

Wire length should be no more than 250 ft (76 m). Use 22 AWG or larger for

normal wiring applications. Continuous wire lengths over 100 ft (30.5 m) should

use 20 AWG or larger.

Advertising