ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury

or death.
DO NOT connect furnace HUM terminal directly to

Thermidistat Control HUM terminal. This will bypass furnace

safety controls. See Low Voltage Wiring Diagrams and notes

for proper connection.

!

WARNING

Dehumidify Equipment and Connections

The dry contact output connects to the dehumidify input on variable−speed

furnaces and fan coils. Additional dehumidification is done by controlling the

compressor. A variety of operating modes are available. The dry contact must be

configured for dehumidification in setup Option 19. See Wiring Diagrams for

more information.

Outdoor Temperature Sensor (TSTATCCSEN01−B)

Outdoor air temperature sensor is included in the box with the Thermidistat

Control. Optimum performance is obtained when an outdoor temperature sensor

is used with the Thermidistat Control. Plan installation so that 2 wires can be run

from Equipment Control Module to an outdoor location, preferably on the north

side of the house or refer to Installation Instructions included with the outdoor

temperature sensor for simplified connection. Sensor can be mounted to outdoor

unit and existing control wires may be used for its connection. Details are

provided in sensor instructions.