B&C Technologies DI-475 Industrial User Manual

Page 23

Advertising
background image

4. STEAM DAMPER SYSTEM OPERATION

The DA-475 Steam damper allows the coil to stay constantly charged eliminating repeated

expansion and contraction. When the damper is opened, the air immediately passes through

the already hot coil, providing instant heat to start the drying process. When the damper is

closed, ambient air is drawn directly into the basket (tumbler), allowing a rapid cool down.

Diagram 1 shows the damper in the heating (open) mode, allowing heat into the basket

(tumbler).

Diagram 2 shows the damper in the cool (closed) mode, pulling ambient air directly into the

basket (tumbler) without passing through the coils.

NOTE:

With the dryer off or with no air supply, the damper is in the cool

down mode.

5. STEAM DAMPER AIR CYLINDER (FLOW CONTROL) OPERATION ADJUSTMENT

Damper operation was tested and adjusted prior to shipping at 80 psi. If damper air

adjustment is necessary, locate flow control valve and make necessary adjustments.

Advertising