ACHIEVED.

Set Up

The single adjustment on the

Series 154-A11NB

OR 21B

Determines the amount of starting voltage

First applied to the motor. When rotated fully

Counterclockwise, the lowest starting

Voltage is obtained. As the adjustment is

Rotated clockwise, the starting voltage is

Increased. When rotated fully clockwise,

The controller will produce approximately

An across the line start. The motor will

Receive full voltage within about one half

(1/2) second.

To set up the controller for the best soft start:

1) Fill the basket (tumbler) with a normal size

Load.

2) Rotate the adjustment fully counter clockwise.

This will give the motor the lowest starting

Voltage and the longest starting time.

3) Start the motor. When properly set, the

Motor shaft should start to rotate when

The start button is pushed. If the motor

Does not start to rotate when the start

Button is pushed but is delayed for several seconds, turn the motor off and rotate

The adjustment in the clockwise direction. This will increase the starting voltage

And decrease the starting time.

4) Restart the motor. Continue to readjust the setting until an acceptable start is

Obtained-clockwise for a harder start-counterclockwise for a softer start.