B&C Technologies DI-475 Industrial User Manual

Page 30

Advertising
background image

D. SAFETY DEVICES

1. Load Door Switches

There are two (2) of these switches located under the main loading doors. These switches

Ensure that the doors are closed before the dryer can start. If the dryer is started when the

load doors are open, the microprocessor controller (computer) L.E.D. display will show “door”

2. Lint Basket Switch

This switch ensures that the lint basket is closed be before the dryer can start. This switch is

located at the front of the dryer at the right side of lint basket. If the lint basket is open when

the dryer is started, then the microprocessor controller (Computer) L.E.D. display will show

“door”

3. Basket (tumbler) Hi-Limit Safety Thermostat

This disc temperature switch has a setting of 225 F. It is located below the basket (tumbler)

on the temperature sensor bracket, along side the computer sensor, and is an automatic

reset type of switch. Access to this switch is gained by sliding/pulling the lint basket/drawer

completely out of the dryer.

This switch backs up the computer sensor and in case of a computer sensor malfunction will

prevent the basket’s (tumbler’s) temperature from becoming excessive. If this switch trips, the

gas flow to the burner box will be shut down; However, the basket (tumbler) will still rotate

4. Burner Box Hi-limit Safety Thermostat

(GAS DRYERS ONLY)

This disc temperature switch has a setting of 330 F. It is located on the right side of the

burner

box, and is an automatic reset type of switch. This switch ensures that there is proper airflow

through the burner box. Upon a low airflow condition, which ensures may be caused by a

clogged lint screen, excessively long or blocked exhaust duct, or improper make-up air, the

temperature in the burner box will increase tripping this switch. This will shut off the gas flow

to the burner box; However, the basket (tumbler) will still run.

5. Sail Switch

(GAS DRYERS ONLY)

The sail switch is located in the front top of the burner box. A sail switch consists of a round

damper plate on a lever arm which is in contact with an electric switch. When the air blower

comes on, it draws air through the gas burner. This creates a negative pressure inside the

burner box, and this negative pressure pulls in the round damper and activates the sail

switch. If there is an improper (low) airflow through the dryer, the sail switch damper will not

pull in, preventing the heat from

Low airflow through the dryer will be caused by overly long or blocked exhaust ducting, lack

of make-up air, or a clogged lint screen.

E. STEAM DAMPER ACTUATOR SYSTEM

This system consists of a hinged damper plate, pneumatic piston, and 24-volt solenoid valve

with a needle valve to control the speed of the piston actuation.

Advertising