B&C Technologies DI-475 Industrial User Manual

Page 37

Advertising
background image

3. Adjustments for reduced voltage soft controllers

This procedure to be used with ALL Series 154-A11NB OR 21B OR 25 control styles.

To properly adjust a soft start controller to give a satisfactory start, two characteristics

Of the motor and load

must be

considered. The frictional load determines the amount

Of torque required to break-away or obtain initial movement of the motor and load. A

System with a high frictional load will require a higher setting of the

START TORQUE

Adjustment than a system with little or no frictional load. Second, the amount of inertia

In the system will determine the

START TIME

adjustment setting. Generally, systems

With low inertia will require a long

START TIME

adjustment to give a satisfactory start,

Whereas, systems with inertia may need only a very short

START TIME

. The softest

Possible start will occur when the start time adjustment is set to maximum and the

Initial torque adjustment is set at the point where the motor just starts the tumbler

Moving when power is first applied.

a.

START TORQUE

Adjustment

The

START TORQUE

adjustment is factory preset for maximum torque (maximum

Starting voltage).

1) Rotate the

START TIME

adjustment fully clockwise so that the longest starting

Time is obtained.

2) Rotate the

START TORQUE

adjustment to midrange on the dial which will lower

The starting torque.

3) Start the motor. If more or less torque is desired, turn off the power, and rotate

The

START TORQUE

adjustment in the appropriate direction until an acceptable

Soft start is obtained.

b.

START TIME

Adjustment

The

START TIME

adjustment range is

½

to 30 seconds. The higher the valve of

The

START TORQUE,

the shorter the duration of the overall time period.

1) During the

START TORQUE,

adjustment process, the

START TIME

was

Adjusted for the longest start possible. If a shorter time is required, rotate the

Adjustment counterclockwise.

2) Start the motor and determine if the soft start is acceptable.

a) If not, continue to rotate the

START TIME

adjustment until an acceptable

Start is obtained.

Advertising