F. DRIVE SYSTEM SOFT START

The DA-475 dryer is equipped with either a Series

154-A11NB

OR 21B

soft start control.

ALL

soft start controls are factory preset. Re-adjustment should not be necessary.

1. Series 154-A11NB OR 21B Drive System Soft Start

Wiring

The

Series 154-A11NB

OR 21B is a motor controller and is used with an electromechanical

motor starter. The controller is wired after the motor starter as shown in the

illustration

below.

The output side of the motor starter should be wired to the line terminals on the controller,

(L1,L2,L3). The load terminals on the controller, (T1,T2,T3) then

Should be

wired to the

motor.

When the motor starter is turned on, 3-phase (3 ) power will be applied to the input to the

controller. The controller will then ramp up the voltage to the motor. The duration of the ramp

will

depend on the setting of the soft start adjustment. When the motor starter is turned off, the

controller will reset and will be ready for the starter to be turned on again.

NOTE:

THE STARTER MUST REMAIN OFF FOR A MINIMUM OF

½ SECOND TO ALLOW

THE CONTROLLER TO COMPLETELY RESET IF THE STARTER IS TURNED ON

BEFORE THE CONTROLLER RESETS, AN ACCEPTABLE SOFT START MAY BE

Advertising