SECTION 7

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and

THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS ARE

REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING,

INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA

( Occupational Safety and Health Administration ) STANDARDS.

The information provided will help isolate the most probable component (s) associated

With the difficulty described. The experienced technician realizes, however, that a Loose

connection or broken/shorted wire may be at fault where electrical components

are concerned…not necessarily the suspected component itself. Electrical parts should

always

be checked for failure before being returned to the factory.

IMPORTANT:

When replacing blown fuses, the replacement

must be

of the exact rating as

the

fuse being replaced. The information provided

should not

be misconstrued as

a handbook for use by an untrained person in making repairs

WARNING: ALL

SERVICE AND TROUBLESHOOTING

SHOULD BE

PERFORMED

BY A QUALIFIED PROFESSIONALOR SERVICE AGENCY.

WARNING:

WHILE MAKING REPAIRS, OBSERVE

ALL

SAFETY PRECAUTIONS

DISPLAYED ON THE DRYER OR SPECIFIED IN THIS MANUAL

A. No display…

1. Service panel fuses blown or tripped breaker

2. Blown

FU1

fuse 1 or

FU2

fuse 2

3. Failed microprocessor controller (computer)

B. Drive motor not operating (does not start)…

* Microprocessor controller (computer) relay output indicator (either) forward

“FWD” or reverse “REV” is on

1. Blown drive motor contactor fuse (s)

2. Failed drive motor contactor

3. Failed drive motor

4. Failed soft start

* Microprocessor controller (computer) relay output indicator (neither) forward

“FWD” or reverse “REV” go on