Global parameters, Program specific parameters, 4 global parameters – B&C Technologies PF Series User Manual

Page 33: 5 program specific parameters

Advertising
background image

9.4

Global Parameters

The following parameters apply globally for the machine. They are always used no matter which
program is currently chosen.

Table 9.6: Global Parameters

Number

Description

Units

Standard value

Set value

1

Preselected program number

100

2

Empty piles on program change

0/1

1

3

Reset counter when changing program

0/1

0

4

Total counter on start page

0/1

0

5

Correction piece length after TE stop

mm

-50

6

Adjust ski width not until LE PhC XF 1

0/1

0

7

Correct piece length Photo A

0-2

0

8

Minimal piece length

mm

200

10

Duration stop stacker before flaps open

ms

350

11

Duration stacker flaps open

ms

250

12

Duration delay stacker flaps

ms

0

15

Delay push out pile

ms

500

16

Duration push out pile

ms

1000

17

Delay belt after push out

ms

0

20

Duration until jam Photocell dark

ms

3000

22

Interval pulse blowing

ms

80

23

Pulse duration

ms

40

25

Number of pieces until jam LF

3

26

Number of pieces until jam XF

4

70

Delay deploy cylinders

ms

300

80

Persist interval statistics

s

600

81

Persist interval time statistics

s

600

85

Piece length endurance run

mm

1000

86

Cycle time endurance run

ms

3500

90

Language

0-5

0

95

Duration until automatic switch-off

s

300

98

Duration until pasknife reset

s

3600

99

Current program number

0-99

0

9.5

Program Specific Parameters

The following parameters can be adjusted differently per program.