LogicPLUS-S Two-Wire Controller

13

Fertigation will start at the conclusion of the programmed Pre-wet cycle and will automatically ac-

tivate the fertigation receiver. If only fertigation time is programmed and no pre-wet time is pro-

grammed, fertigation will start at the commencement of the valve run time programmed. This receiv-

er will remain activated for as long as the fertigation is programmed. If the total valve run time is 15

minutes, pre wet for 3 minutes and fertigation for 5 minutes, then there will be 7 minutes remaining

of valve run time after the fertigation cycle ends.

nOTe: At no time will the controller permit the total time of pre-wet and fertigation to exceed

the total run time programmed. no pre-wet run times need to be programmed in order to run

the fertigation mode.

nOTe: Program 6 can only be set in minutes and seconds, as all other programs can be set

in hours and minutes. The maximum run times can be set from 1 minute to 10 hours and 59

minutes on all programs except 6, which can be set for a minimum of 10 seconds to a maxi-

mum of 59 minutes and 59 seconds. With the water budget feature (position 8) these run

times can be increased or decreased from 0% to 250% in 5% increments.

nOTe: A maximum of any 8 receivers/valves (any combination) may be operated

simultaneously.