LogicPLUS-S Two-Wire Controller

22

22

Position 9 | | Test Cycle | | Function Button - Short Test

Use set 1 to set run times in minutes, use set 2 to set run time of seconds for test cycle, set 3 has no

response, and use set 4 to select valve range to test, display will change, use set 1 or set 2 to select

valve range start and end, use set 3 to select Master A, B or C if required, use set 4 to start test cycle,

press set 4 again to stop test cycle.

The controller will immediately run each valve in sequence for valve range and predetermined run

time for visual review of the system operation.

note: The pause setting in position 3 for program 1 will determined the amount of pause

between stations during the test cycle operation.

Use set 5 Function Button to perform a short test.

Short Test

This feature to be used for troubleshooting. See page 32.

Position 10

| | Semi / Manual / Program / Master Clear | | Current Monitoring Special Function