Hit Products LogicPLUS S 42/128 User Manual

Page 4

Advertising
background image

LogicPLUS-S Two-Wire Controller

4

4

Field Wire Outputs

4

4

Minimum Wire Size

14 gauge

14 gauge

Maximum Wire Run

12,000 Feet

12,000 Feet

Maximum Number of Receivers

80

128

Receivers Programmable

and Re-Programmable

Yes

Yes

On Board Receiver

Programming

Capability

Yes

Yes

Remote Receiver

Programming

use LP-HHRP

Yes

Yes

Security Password

Yes

Yes

enclosure:

Box - Stainless steel, locking, wall or pedestal mount.

Pedestal – Stainless steel
See diagram page 45 for box and pedestal dimensions.

input Power:

110VAC, 240VAC 50/60Hz

Solar 12V DC

Grounding:

Enclosure grounded to utility ground. SPD/Output board grounds with 8 foot ground rod.
See diagram page 35, 36

Surge/Lightning Protection:

Controller Surge Protection is provided by an assembly mounted below the controller panel. This

board and its components are like a sophisticated fuse. It will blow in an attempt to save the main

circuit board from destruction by line surges mainly created by lightning. It is connected to the

main board with a simple cable for easy removal for testing and replacement if necessary.
See diagram page 34

Field Surge Protection is provided by the use of LP-SPD-F devices. Designed to be installed in

valve boxes every 200-300 feet and attached to a ground rod. Rod is customer supplied.
See diagram page 43