CANOGA PERKINS L351 10/100BASE Media Converter User Manual

Page 41

Advertising
background image

EdgeAccess Universal Chassis System

L351 10/100BASE Media Converter

4-17

4.5.4 Alarm Output Configuration

Use the Alarm Output Configuration screen to set any or all alarms to Major, Minor, or Off. See
Figure 4-15 and Table 4-3. To configure alarms, follow these steps:

1. From the Main Menu type

3

, Alarm Output Configuration, and press <Enter>. The Alarm Output

Configuration screen appears.

2. Type the number for the alarm you want to set and press <Enter>.

3. Press <Space> to cycle to Major, Minor, or Off, and press <Enter>.

Figure 4-15. Alarm Output Configuration Screen

Table 4-3. Alarm Output Definitions

Alarm Description

2) Link Down

Loss of Signal (electrical)/Composite Loss of Signal (optical);
one or both received signals fail; default is Off

3) RMTF

Remote fault received; default is Off

4) LLF

Link loss forwarded to module; default if Off

5) Configuration

Setup errors, including mismatches with other modems; default
is Off

6) Power/Fan/Temperature

Power is low or fan is off; default is Minor

7) SBMC Loss

SideBand management signal lost; default is Off

8) Power-On Self Test

Modem failed when power was turned on; default is Off

9) SFP Transmitter Warning

10) SFP Transmitter Failure

Note: You must enable the Alarm Output item on the System Status & Configuration screen for

these settings to take effect.

--------------------------ALARM OUTPUT CONFIGURATION------------------

1) Factory Defaults

2) Link Down Alarm Minor
3) RMTF Alarm Major
4) LLF Alarm Major
5) Configuration Alarm Off
6) Power/Fan/Temperature Alarm Minor
7) SBMC Loss Alarm Major
8) Power-On Self Test Alarm Major
9) SFP Transmitter Warning Minor
10) SFP Transmitter Failure Major

Select [1-10]:

-------------------------------Messages-------------------------------